Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ Plug-in Options ]

1-10 of Total 30

prev 1 / 3page next
  • Error of the communication option

    E.OP1 indicates the communication line error. E.1 indicates a hardware fault of the communication option. (It is judged as the hardware fault when the commun... More Details >>

    • No:20805
    • Release Date:2018/08/22 16:24
  • Parameter writing via CC-Link

    Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>

    • No:21976
    • Release Date:2018/08/22 16:30
  • Resetting inverter after restoring from power failure

    When the programmable controller power is turned OFF while the inverter is in the PLC link operation mode, a communication error occurs and the inverter trip... More Details >>

    • No:21417
    • Release Date:2018/08/22 16:27
  • Plug-in options

    Up to three plug-in options can be mounted. More Details >>

    • No:21093
    • Release Date:2018/08/22 16:25
  • Digital input and maximum frequency

    1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>

    • No:22098
    • Release Date:2018/08/22 16:30
  • FR-A8AP

    The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>

    • No:21002
    • Release Date:2018/08/22 16:25
  • FR-A8AX/A8AY

    For the FR-A700/F700, the hook is cut off for the wiring due to restrictions on the structure. These restrictions are eliminated for the FR-A800/F800. More Details >>

    • No:21051
    • Release Date:2018/08/22 16:25
  • FR-A8AY

    The response delay time is 10 ms normally and 100 ms at startup. More Details >>

    • No:20821
    • Release Date:2018/08/22 16:24
  • FR-A8NC

    Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>

    • No:20812
    • Release Date:2018/08/22 16:24
  • 12-bit digital input

    You can set both the BCD code and binary code inputs within the range from 0 to 400 Hz.You can set the bias and gain in 0.01 Hz units.For BCD input, when the... More Details >>

    • No:21945
    • Release Date:2018/08/22 16:30

1-10 of Total 30