FAQ
FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Plug-in Options
FAQ
Keyword Search
FAQ within [ Plug-in Options ]
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
-
The same EDS files cannot be used for the different models. Download the EDS files for F800 from the following page of Mitsubishi Electric FA Global Website ... More Details >>
- No:20955
- Release Date:2018/08/22 16:25
-
When the PG24 terminal and the PG terminal are shorted, 24 VDC power for the encoder can be supplied from the PG24 terminal. More Details >>
- No:20954
- Release Date:2018/08/22 16:25
-
It is because the CC-Link monitor is designed to hold the value at an error occurrence. More Details >>
- No:20946
- Release Date:2018/08/22 16:25
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
-
The frequency setting in the communication cannot be used together with FR-A8AX. The priority of the FR-A8AX is equal to the second terminal analog input and... More Details >>
- No:20917
- Release Date:2018/08/22 16:25
-
Yes, it is. More Details >>
- No:20874
- Release Date:2018/08/22 16:24
-
Because the inverter status reading is stopped by the processing such as PLC in the inverter when the main circuit turns ON. It is stopped for approximately ... More Details >>
- No:20873
- Release Date:2018/08/22 16:24
-
The standard product is not coated. The FR-A8AY-60 is the coated model. More Details >>
- No:20872
- Release Date:2018/08/22 16:24
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
21-30 of Total 30