  • FR-A8AY

    The response delay time is 10 ms normally and 100 ms at startup. More Details >>

    • No:20821
    • Release Date:2018/08/22 16:24
  • Digital input and maximum frequency

    1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>

    • No:22098
    • Release Date:2018/08/22 16:30
  • FR-A8AL

    When the PG24 terminal and the PG terminal are shorted, 24 VDC power for the encoder can be supplied from the PG24 terminal. More Details >>

    • No:20954
    • Release Date:2018/08/22 16:25
  • CC-Link

    The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>

    • No:21142
    • Release Date:2018/08/22 16:26
  • FR-A7AP, FR-A7AL

    They are conducted. An internal circuit is built-in to prevent undesirable current of the encoder power supply and inverter. More Details >>

    • No:21124
    • Release Date:2018/08/22 16:26
  • 12-bit digital input

    You can set both the BCD code and binary code inputs within the range from 0 to 400 Hz.You can set the bias and gain in 0.01 Hz units.For BCD input, when the... More Details >>

    • No:21945
    • Release Date:2018/08/22 16:30
  • FR-A7NF

    Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>

    • No:21121
    • Release Date:2018/08/22 16:26
  • FR-A8TP

    Yes, it is. More Details >>

    • No:20874
    • Release Date:2018/08/22 16:24
  • FR-A8TR

    Because when the FR-A8NC and FR-A8TR are used together, the wiring to the terminals becomes physically difficult. More Details >>

    • No:20876
    • Release Date:2018/08/22 16:24
  • CC-Link

    It is because the CC-Link monitor is designed to hold the value at an error occurrence. More Details >>

    • No:20946
    • Release Date:2018/08/22 16:25