FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Plug-in Options
FAQ
Keyword Search
FAQ within [ Plug-in Options ]
-
Yes, it is. More Details >>
- No:20874
- Release Date:2018/08/22 16:24
-
The frequency setting in the communication cannot be used together with FR-A8AX. The priority of the FR-A8AX is equal to the second terminal analog input and... More Details >>
- No:20917
- Release Date:2018/08/22 16:25
-
The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>
- No:21142
- Release Date:2018/08/22 16:26
-
It is because the CC-Link monitor is designed to hold the value at an error occurrence. More Details >>
- No:20946
- Release Date:2018/08/22 16:25
-
Because when the FR-A8NC and FR-A8TR are used together, the wiring to the terminals becomes physically difficult. More Details >>
- No:20876
- Release Date:2018/08/22 16:24
-
When the PG24 terminal and the PG terminal are shorted, 24 VDC power for the encoder can be supplied from the PG24 terminal. More Details >>
- No:20954
- Release Date:2018/08/22 16:25
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
-
The standard product is not coated. The FR-A8AY-60 is the coated model. More Details >>
- No:20872
- Release Date:2018/08/22 16:24
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
-
They are conducted. An internal circuit is built-in to prevent undesirable current of the encoder power supply and inverter. More Details >>
- No:21124
- Release Date:2018/08/22 16:26
21-30 of Total 30