  • Error of the communication option

    E.OP1 indicates the communication line error. E.1 indicates a hardware fault of the communication option. (It is judged as the hardware fault when the commun... More Details >>

    • No:20805
    • Release Date:2018/08/22 16:24
  • Resetting inverter after restoring from power failure

    When the programmable controller power is turned OFF while the inverter is in the PLC link operation mode, a communication error occurs and the inverter trip... More Details >>

    • No:21417
    • Release Date:2018/08/22 16:27
  • Digital input and maximum frequency

    1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>

    • No:22098
    • Release Date:2018/08/22 16:30
  • FR-A800 and Ethernet IP communication

    Yes. the options support it. By connecting the following communication option (built-in circuit board) manufactured and sold by HMS to the FR-A800 series, th... More Details >>

    • No:20823
    • Release Date:2018/08/22 16:24
  • Parameter writing via CC-Link

    Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>

    • No:21976
    • Release Date:2018/08/22 16:30
  • Plug-in options

    The conventional plug-in option (FR-A7[][]) cannot be used. Use the dedicated plug-in option (FR-A8[][]). More Details >>

    • No:21114
    • Release Date:2018/08/22 16:25
  • Encoder feedback speed accuracy

    The speed variation rate is as follows:  - Encoder feedback control: ±0.2% - Vector control: ±0.02% (mentioned in FR-A5AP Instruction Manual) More Details >>

    • No:21422
    • Release Date:2018/08/22 16:27
  • FR-A8ND

    The same EDS files cannot be used for the different models. Download the EDS files for F800 from the following page of Mitsubishi Electric FA Global Website ... More Details >>

    • No:20955
    • Release Date:2018/08/22 16:25
  • FR-A8AY

    The response delay time is 10 ms normally and 100 ms at startup. More Details >>

    • No:20821
    • Release Date:2018/08/22 16:24
  • Plug-in options

    You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>

    • No:21656
    • Release Date:2018/08/22 16:28