The operation panel is also compatible with the IP55 More Details >>
- No:21091
- Release Date:2018/08/22 16:25
-
By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>
- No:21106
- Release Date:2018/08/22 16:25
-
UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>
- No:20978
- Release Date:2018/08/22 16:25
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
-
The output turns OFF (0 mA) during the inverter reset. More Details >>
- No:20921
- Release Date:2018/08/22 16:25
-
Fuses are not required as peripheral devices for the FR-A802, which has internal fuses. More Details >>
- No:21019
- Release Date:2018/08/22 16:25
-
Winding diameter calculation of the FR-A800-R2R
Z phase is not required for the thickness method. More Details >>
- No:20855
- Release Date:2018/08/22 16:24
-
The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>
- No:20923
- Release Date:2018/08/22 16:25
-
Yes, they can. More Details >>
- No:20856
- Release Date:2018/08/22 16:24
-
When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>
- No:21073
- Release Date:2018/08/22 16:25