FAQ within [ FREQROL-A800 ]

91-100 of Total 142

prev 10 / 15page next
  • FR-A800-R2R

    The calculation is performed by two modes. One method calculates the current winding diameter automatically by moving the dancer roll from lower limit positi... More Details >>

    • No:20924
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It is not possible because the RS-485 terminal block is not installed. Use the FR-A800 (RS-485 communication type) when performing the RS-485 communication. More Details >>

    • No:20881
    • Release Date:2018/08/22 16:24
  • PLC function

    SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>

    • No:21057
    • Release Date:2018/08/22 16:25
  • Setting resolution

    V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>

    • No:20960
    • Release Date:2018/08/22 16:25
  • FR-A800-2

    The output turns OFF (0 mA) during the inverter reset. More Details >>

    • No:20921
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • Reduced impact restart

    Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>

    • No:20904
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    There are some restrictions compared to the FR-A800 (RS-485 communication type). For example, the FR-A8TR is unavailable, and only two option connectors are ... More Details >>

    • No:20884
    • Release Date:2018/08/22 16:24
  • FR-A800

    Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>

    • No:21104
    • Release Date:2018/08/22 16:25
  • FR-A800

    The operation panel is also compatible with the IP55 More Details >>

    • No:21091
    • Release Date:2018/08/22 16:25

91-100 of Total 142