- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A800
FAQ
Keyword Search
FAQ within [ FREQROL-A800 ]
-
The storage areas for the sequence programs and for the parameters of the inverter are different. More Details >>
- No:20958
- Release Date:2018/08/22 16:25
-
Turning ON the main circuit power stops the 24 V external power supply operation and enables the normal operation. Therefore, the separate power supply canno... More Details >>
- No:21018
- Release Date:2018/08/22 16:25
-
A capacitive filter and common mode choke are built in. (A common mode choke is built in only for the 55K or lower.) Use a connector for whether to turn ON o... More Details >>
- No:21094
- Release Date:2018/08/22 16:25
-
It cannot be connected. When using DU08, connect it to the PU connector. More Details >>
- No:21111
- Release Date:2018/08/22 16:25
-
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
- No:20905
- Release Date:2018/08/22 16:25
-
Parameter copy to the USB memory
Yes. Parameters can be read except during an inverter reset or when the password function is set. More Details >>
- No:20961
- Release Date:2018/08/22 16:25
-
SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>
- No:21057
- Release Date:2018/08/22 16:25
-
Yes. More Details >>
- No:21062
- Release Date:2018/08/22 16:25
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
101-110 of Total 142