FAQ within [ FREQROL-A800 ]

101-110 of Total 142

prev 11 / 15page next
  • PLC function

    The number of timer points is 16 for the high speed and low speed in total. More Details >>

    • No:21056
    • Release Date:2018/08/22 16:25
  • FR-A800

    Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>

    • No:20976
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • Residual voltage at the output shutoff

    The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>

    • No:20906
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    Yes. It can be carried out like under the dancer feedback speed control. More Details >>

    • No:20885
    • Release Date:2018/08/22 16:24
  • FR-A800

    By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>

    • No:21106
    • Release Date:2018/08/22 16:25
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25
  • FR-A800

    Number of terminals: Same input terminals as the A700 series, and the following two terminals are added. Safety: SI1, SI2, SIC 24 V power supply: +24 * The t... More Details >>

    • No:21099
    • Release Date:2018/08/22 16:25
  • Trace data

    The trace data is stored in the built-in RAM of the inverter and deleted when the power is turned OFF or the inverter is reset. The data can be held with any... More Details >>

    • No:21078
    • Release Date:2018/08/22 16:25
  • PLC function

    When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>

    • No:21073
    • Release Date:2018/08/22 16:25