  • FR-A800-R2R

    A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>

    • No:20926
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>

    • No:20915
    • Release Date:2018/08/22 16:25
  • Reduced impact restart

    Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>

    • No:20904
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>

    • No:20887
    • Release Date:2018/08/22 16:24
  • FR-A800

    A separate power supply is required according to the encoder power supply specification. More Details >>

    • No:21090
    • Release Date:2018/08/22 16:25
  • Auto tuning

    The 800 series supports the multiple rating. Thus, the rated current of the corresponding motor is 40% or higher of the inverter rated current. (Using a moto... More Details >>

    • No:21085
    • Release Date:2018/08/22 16:25
  • FR-A842

    The inrush current limit circuit is not built in the FR-A842 (inverter unit). It is built in the FR-CC2 (converter unit), which is combined with the FR-A842.... More Details >>

    • No:21059
    • Release Date:2018/08/22 16:25
  • FR-A800

    When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>

    • No:20981
    • Release Date:2018/08/22 16:25
  • FR-A800

    Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>

    • No:20976
    • Release Date:2018/08/22 16:25
  • Built-in PLC function

    The error indicates that the parameter setting of the PLC function is not set. It is considered that the PC parameter is not checked when the PC parameter an... More Details >>

    • No:20859
    • Release Date:2018/08/22 16:24