  • Residual voltage at the output shutoff

    The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>

    • No:20906
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It is available if the CC-Link option of the FR-A8NC is installed. More Details >>

    • No:20894
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    There are some restrictions compared to the FR-A800 (RS-485 communication type). For example, the FR-A8TR is unavailable, and only two option connectors are ... More Details >>

    • No:20884
    • Release Date:2018/08/22 16:24
  • Frequency setting increment

    The value is displayed in 0.1 rpm increments under Vector control. However, the value is rounded down to the first decimal place and displayed in 1 rpm incre... More Details >>

    • No:21021
    • Release Date:2018/08/22 16:25
  • MM-FR-A800

    If the command is 0.01 Hz or higher, the positioning control is performed. More Details >>

    • No:21001
    • Release Date:2018/08/22 16:25
  • Communication specifications for connection of multiple inverters

    Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>

    • No:20998
    • Release Date:2018/08/22 16:25
  • FR-A800-CRN

    The inverter with circuit board coating (conforming to IEC60721-3-3 3C2/3S2) ensures reliability even in poor environments. Furthermore, the inverter with pl... More Details >>

    • No:20975
    • Release Date:2018/08/22 16:25
  • Reduced impact restart

    Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>

    • No:20904
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>

    • No:20891
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>