  • FR-A800-R2R

    The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>

    • No:20845
    • Release Date:2018/08/22 16:24
  • Europe EMC Directive compliance

    By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>

    • No:21116
    • Release Date:2018/08/22 16:26
  • MM-FR-A800

    If the command is 0.01 Hz or higher, the positioning control is performed. More Details >>

    • No:21001
    • Release Date:2018/08/22 16:25
  • FR-A800

    It is based on the maximum value that can be set for frequency. Specifically, it is 400 Hz. More Details >>

    • No:20979
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>

    • No:20888
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>

    • No:20891
    • Release Date:2018/08/22 16:24
  • FR-A8TAT

    Yes, it does. (There are some restrictions. More Details >>

    • No:21082
    • Release Date:2018/08/22 16:25
  • Anti-sway control

    Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>

    • No:20953
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>

    • No:20839
    • Release Date:2018/08/22 16:24
  • FR-A800

    When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>

    • No:20981
    • Release Date:2018/08/22 16:25