  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It is available if the CC-Link option of the FR-A8NC is installed. More Details >>

    • No:20894
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>

    • No:20839
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    The encoder feedback is always required for the thickness calculation function. The actual line speed calculation function requires the input of the actual l... More Details >>

    • No:20890
    • Release Date:2018/08/22 16:24
  • Europe EMC Directive compliance

    By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>

    • No:21116
    • Release Date:2018/08/22 16:26
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25
  • Frequency setting increment

    The value is displayed in 0.1 rpm increments under Vector control. However, the value is rounded down to the first decimal place and displayed in 1 rpm incre... More Details >>

    • No:21021
    • Release Date:2018/08/22 16:25
  • Installation of a fuse

    Fuses are not required as peripheral devices for the FR-A802, which has internal fuses. More Details >>

    • No:21019
    • Release Date:2018/08/22 16:25
  • Life measurement of the main circuit capacitor

    No. Turn OFF and ON both main circuit and control circuit. More Details >>

    • No:20999
    • Release Date:2018/08/22 16:25
  • Anti-sway control

    No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>

    • No:20952
    • Release Date:2018/08/22 16:25