  • Setting values of the FR-F800 when replaced with the FR-F400

    The performance and noise countermeasure were improved and the initial value is set to "8". Try with the initial value "2" first. If the noise is distracting... More Details >>

    • No:20808
    • Release Date:2018/08/22 16:24
  • FR-A800

    No alarm occurs due to the abnormal temperature. In the main circuit, alarms such as heatsink overheat will be occurred. More Details >>

    • No:20977
    • Release Date:2018/08/22 16:25
  • Setting resolution

    V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>

    • No:20960
    • Release Date:2018/08/22 16:25
  • Carrier frequency automatic reducing function

    The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>

    • No:20903
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It is not possible because the RS-485 terminal block is not installed. Use the FR-A800 (RS-485 communication type) when performing the RS-485 communication. More Details >>

    • No:20881
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    Yes, it can like the standard product. More Details >>

    • No:20880
    • Release Date:2018/08/22 16:24
  • CC-Link IE Field Basic

    Only the FR-A800/F800-E series is supported by CC-Link IE Field Basic. (As of March 2017) The FR-A800-GF and FR-A8NCE supported by CC-Link IE Field are not s... More Details >>

    • No:20858
    • Release Date:2018/08/22 16:24
  • MM-FR-A800

    If the command is 0.01 Hz or higher, the positioning control is performed. More Details >>

    • No:21001
    • Release Date:2018/08/22 16:25
  • Communication specifications for connection of multiple inverters

    Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>

    • No:20998
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    Yes. It can be carried out like under the dancer feedback speed control. More Details >>

    • No:20885
    • Release Date:2018/08/22 16:24