Monitoring function of the FR-A800-R2R
Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>
- No:20914
- Release Date:2018/08/22 16:25
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
-
The encoder feedback is always required for the thickness calculation function. The actual line speed calculation function requires the input of the actual l... More Details >>
- No:20890
- Release Date:2018/08/22 16:24
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
-
Yes, it can like the standard product. More Details >>
- No:20880
- Release Date:2018/08/22 16:24
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
-
The error indicates that the parameter setting of the PLC function is not set. It is considered that the PC parameter is not checked when the PC parameter an... More Details >>
- No:20859
- Release Date:2018/08/22 16:24
-
Up to 64 (slave stations). The number of connectable units differs depending on the master station. More Details >>
- No:20857
- Release Date:2018/08/22 16:24
-
It cannot be connected. When using DU08, connect it to the PU connector. More Details >>
- No:21111
- Release Date:2018/08/22 16:25