FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A800
FAQ
Keyword Search
FAQ within [ FREQROL-A800 ]
-
The output turns OFF (0 mA) during the inverter reset. More Details >>
- No:20921
- Release Date:2018/08/22 16:25
-
It is available if the CC-Link option of the FR-A8NC is installed. More Details >>
- No:20894
- Release Date:2018/08/22 16:24
-
Fuses are not required as peripheral devices for the FR-A802, which has internal fuses. More Details >>
- No:21019
- Release Date:2018/08/22 16:25
-
It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>
- No:20889
- Release Date:2018/08/22 16:24
-
The FR-A800 has metal installation holes regardless of the capacity. More Details >>
- No:20980
- Release Date:2018/08/22 16:25
-
V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>
- No:20960
- Release Date:2018/08/22 16:25
-
Monitoring function of the FR-A800-R2R
Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>
- No:20914
- Release Date:2018/08/22 16:25
-
Position control is available under vector control with an encoder. Under PM sensorless vector control in combination with a MM-CF motor, simple positioning ... More Details >>
- No:21105
- Release Date:2018/08/22 16:25
-
Parameter copy to the USB memory
Yes. Writing is available when the power supply specification or capacity is different. Note that setting values of the voltage relation is also overwritten ... More Details >>
- No:21013
- Release Date:2018/08/22 16:25
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
121-130 of Total 142