  • FR-A800-R2R

    When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>

    • No:20974
    • Release Date:2018/08/22 16:25
  • Anti-sway control

    No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>

    • No:20952
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>

    • No:20888
    • Release Date:2018/08/22 16:24
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25
  • FR-A800

    The FR-A800 has metal installation holes regardless of the capacity. More Details >>

    • No:20980
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • FR-A800

    Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>

    • No:21104
    • Release Date:2018/08/22 16:25
  • FR-A800

    A separate power supply is required according to the encoder power supply specification. More Details >>

    • No:21090
    • Release Date:2018/08/22 16:25
  • FR-A800

    The day of the week is automatically determined from the data of year, month, and day. More Details >>

    • No:20997
    • Release Date:2018/08/22 16:25
  • Vector control

    Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>

    • No:21022
    • Release Date:2018/08/22 16:25