FAQ within [ FREQROL-A800 ]
-
No alarm occurs due to the abnormal temperature. In the main circuit, alarms such as heatsink overheat will be occurred. More Details >>
- No:20977
- Release Date:2018/08/22 16:25
-
The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>
- No:20923
- Release Date:2018/08/22 16:25
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
-
It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>
- No:20839
- Release Date:2018/08/22 16:24
-
Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>
- No:21104
- Release Date:2018/08/22 16:25
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
-
The encoder feedback is always required for the thickness calculation function. The actual line speed calculation function requires the input of the actual l... More Details >>
- No:20890
- Release Date:2018/08/22 16:24
-
No, it is not. It is released by the inverter reset that releases E.OHT. More Details >>
- No:20843
- Release Date:2018/08/22 16:24
-
The gain of the tension PI gain automatic tuning is the one of the dancer feedback speed control. The gain adjusted by speed control P gain compensation is t... More Details >>
- No:20925
- Release Date:2018/08/22 16:25