Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-A800 ]

121-130 of Total 142

prev 13 / 15page next
  • FR-A800-R2R

    When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>

    • No:20974
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>

    • No:20926
    • Release Date:2018/08/22 16:25
  • FR-A800

    When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>

    • No:20981
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>

    • No:20891
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>

    • No:20889
    • Release Date:2018/08/22 16:24
  • FR-A800

    By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>

    • No:21106
    • Release Date:2018/08/22 16:25
  • FR-A800

    The operation panel is also compatible with the IP55 More Details >>

    • No:21091
    • Release Date:2018/08/22 16:25
  • Combination of the FR-A800 and MM-BF

    Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>

    • No:21000
    • Release Date:2018/08/22 16:25
  • STOP function of the FR-A800

    No, it is not. It is released by the inverter reset that releases E.OHT. More Details >>

    • No:20843
    • Release Date:2018/08/22 16:24
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25

121-130 of Total 142