The output turns OFF (0 mA) during the inverter reset. More Details >>
- No:20921
- Release Date:2018/08/22 16:25
-
Monitoring function of the FR-A800-R2R
Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>
- No:20914
- Release Date:2018/08/22 16:25
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
-
No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>
- No:20952
- Release Date:2018/08/22 16:25
-
Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>
- No:21104
- Release Date:2018/08/22 16:25
-
Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>
- No:20953
- Release Date:2018/08/22 16:25
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
-
Fuses are not required as peripheral devices for the FR-A802, which has internal fuses. More Details >>
- No:21019
- Release Date:2018/08/22 16:25
-
When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>
- No:20887
- Release Date:2018/08/22 16:24
-
No, it is not. It is released by the inverter reset that releases E.OHT. More Details >>
- No:20843
- Release Date:2018/08/22 16:24