Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-A800 ]

121-130 of Total 142

prev 13 / 15page next
  • Anti-sway control

    No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>

    • No:20952
    • Release Date:2018/08/22 16:25
  • FR-A800-2

    The output turns OFF (0 mA) during the inverter reset. More Details >>

    • No:20921
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>

    • No:20888
    • Release Date:2018/08/22 16:24
  • FR-A800-CRN

    The inverter with circuit board coating (conforming to IEC60721-3-3 3C2/3S2) ensures reliability even in poor environments. Furthermore, the inverter with pl... More Details >>

    • No:20975
    • Release Date:2018/08/22 16:25
  • Setting resolution

    V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>

    • No:20960
    • Release Date:2018/08/22 16:25
  • Vector control

    Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>

    • No:21022
    • Release Date:2018/08/22 16:25
  • FR-A800

    The day of the week is automatically determined from the data of year, month, and day. More Details >>

    • No:20997
    • Release Date:2018/08/22 16:25
  • FR-A800

    When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>

    • No:20981
    • Release Date:2018/08/22 16:25
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25

121-130 of Total 142

Inquiries