FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A800
FAQ
Keyword Search
FAQ within [ FREQROL-A800 ]
-
The encoder feedback is always required for the thickness calculation function. The actual line speed calculation function requires the input of the actual l... More Details >>
- No:20890
- Release Date:2018/08/22 16:24
-
Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>
- No:21104
- Release Date:2018/08/22 16:25
-
It is based on the maximum value that can be set for frequency. Specifically, it is 400 Hz. More Details >>
- No:20979
- Release Date:2018/08/22 16:25
-
The calculation is performed by two modes. One method calculates the current winding diameter automatically by moving the dancer roll from lower limit positi... More Details >>
- No:20924
- Release Date:2018/08/22 16:25
-
Winding diameter calculation of the FR-A800-R2R
Z phase is not required for the thickness method. More Details >>
- No:20855
- Release Date:2018/08/22 16:24
-
The FR-A800 has metal installation holes regardless of the capacity. More Details >>
- No:20980
- Release Date:2018/08/22 16:25
-
No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>
- No:20952
- Release Date:2018/08/22 16:25
-
A separate power supply is required according to the encoder power supply specification. More Details >>
- No:21090
- Release Date:2018/08/22 16:25
-
Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>
- No:20976
- Release Date:2018/08/22 16:25
-
Fuses are not required as peripheral devices for the FR-A802, which has internal fuses. More Details >>
- No:21019
- Release Date:2018/08/22 16:25
121-130 of Total 142