FAQ within [ FREQROL-A800 ]
-
Parameter copy to the USB memory
Yes. Writing is available when the power supply specification or capacity is different. Note that setting values of the voltage relation is also overwritten ... More Details >>
- No:21013
- Release Date:2018/08/22 16:25
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
-
By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>
- No:21106
- Release Date:2018/08/22 16:25
-
Yes, it does. (There are some restrictions. More Details >>
- No:21082
- Release Date:2018/08/22 16:25
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
-
The operation panel is also compatible with the IP55 More Details >>
- No:21091
- Release Date:2018/08/22 16:25
-
UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>
- No:20978
- Release Date:2018/08/22 16:25
-
The calculation is performed by two modes. One method calculates the current winding diameter automatically by moving the dancer roll from lower limit positi... More Details >>
- No:20924
- Release Date:2018/08/22 16:25
-
If the command is 0.01 Hz or higher, the positioning control is performed. More Details >>
- No:21001
- Release Date:2018/08/22 16:25
-
Number of terminals: There are the same output terminals as A700 and the following terminals (2 points) are added. Safety: SO, SOC * The terminals SO and SOC... More Details >>
- No:21098
- Release Date:2018/08/22 16:25