  • FR-A800

    When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>

    • No:20981
    • Release Date:2018/08/22 16:25
  • Monitoring function of the FR-A800-R2R

    Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>

    • No:20914
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    Yes. It can be carried out like under the dancer feedback speed control. More Details >>

    • No:20885
    • Release Date:2018/08/22 16:24
  • FR-A800

    The operation panel is also compatible with the IP55 More Details >>

    • No:21091
    • Release Date:2018/08/22 16:25
  • Setting resolution

    V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>

    • No:20960
    • Release Date:2018/08/22 16:25
  • FR-A800

    UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>

    • No:20978
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    It is available if the CC-Link option of the FR-A8NC is installed. More Details >>

    • No:20894
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>

    • No:20887
    • Release Date:2018/08/22 16:24
  • FR-A800

    No alarm occurs due to the abnormal temperature. In the main circuit, alarms such as heatsink overheat will be occurred. More Details >>

    • No:20977
    • Release Date:2018/08/22 16:25
  • FR-A800

    Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>

    • No:20976
    • Release Date:2018/08/22 16:25