Yes, the resistance values are the same. More Details >>
- No:21020
- Release Date:2018/08/22 16:25
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
-
Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>
- No:20976
- Release Date:2018/08/22 16:25
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
-
Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>
- No:21104
- Release Date:2018/08/22 16:25
-
The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>
- No:20923
- Release Date:2018/08/22 16:25
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
-
The FR-A800 has metal installation holes regardless of the capacity. More Details >>
- No:20980
- Release Date:2018/08/22 16:25
-
Basically, it depends on machine specifications. Advantage of dancer feedback speed control: Easy control. Small tension can be controlled. Disadvantage: Mac... More Details >>
- No:20973
- Release Date:2018/08/22 16:25
-
A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>