FAQ within [ FREQROL-A800 ]

31-40 of Total 144

prev 4 / 15page next
  • FR-A800

    No, they do not. Pr.72 is invalid at the offline auto tuning. It is also invalid when the motor rotates with Pr.96 = 101. More Details >>

    • No:20878
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>

    • No:20887
    • Release Date:2018/08/22 16:24
  • FR-A800

    The day of the week is automatically determined from the data of year, month, and day. More Details >>

    • No:20997
    • Release Date:2018/08/22 16:25
  • FR-A800-GF/FR-A800-E

    Yes, they can. More Details >>

    • No:20856
    • Release Date:2018/08/22 16:24
  • Vector control

    Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>

    • No:21022
    • Release Date:2018/08/22 16:25
  • FR-A800

    The operation panel is also compatible with the IP55 More Details >>

    • No:21091
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>

    • No:20891
    • Release Date:2018/08/22 16:24
  • FR-A800-2

    The output turns OFF (0 mA) during the inverter reset. More Details >>

    • No:20921
    • Release Date:2018/08/22 16:25
  • FR Configurator2

    Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>

    • No:20840
    • Release Date:2018/08/22 16:24
  • FR-A800-R2R

    The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>

    • No:20845
    • Release Date:2018/08/22 16:24