FAQ within [ FREQROL-A800 ]

31-40 of Total 144

prev 4 / 15page next
  • FR-A800

    Available under vector control with an encoder.* Zero speed and servo lock are available under PM sensorless vector control only in combination with an MM-CF... More Details >>

    • No:21100
    • Release Date:2018/08/22 16:25
  • FR-A800

    - The installation size is compatible for the following capacities. Compatible: 200 V class 90K or lower, 400 V class 7.5K or lower and 18.5K to 280K- The in... More Details >>

    • No:21110
    • Release Date:2018/08/22 16:25
  • Europe EMC Directive compliance

    By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>

    • No:21116
    • Release Date:2018/08/22 16:26
  • FR-A800-R2R

    The encoder feedback is always required for the thickness calculation function. The actual line speed calculation function requires the input of the actual l... More Details >>

    • No:20890
    • Release Date:2018/08/22 16:24
  • Monitoring function of the FR-A800-R2R

    No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>

    • No:20915
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    The gain of the tension PI gain automatic tuning is the one of the dancer feedback speed control. The gain adjusted by speed control P gain compensation is t... More Details >>

    • No:20925
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>

    • No:20926
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    Basically, it depends on machine specifications. Advantage of dancer feedback speed control: Easy control. Small tension can be controlled. Disadvantage: Mac... More Details >>

    • No:20973
    • Release Date:2018/08/22 16:25
  • FR-A800

    No alarm occurs due to the abnormal temperature. In the main circuit, alarms such as heatsink overheat will be occurred. More Details >>

    • No:20977
    • Release Date:2018/08/22 16:25
  • FR-A800

    The FR-A800 has metal installation holes regardless of the capacity. More Details >>

    • No:20980
    • Release Date:2018/08/22 16:25