FAQ within [ FREQROL-A800 ]

61-70 of Total 144

prev 7 / 15page next
  • Setting resolution

    V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>

    • No:20960
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>

    • No:20974
    • Release Date:2018/08/22 16:25
  • PLC function

    When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>

    • No:21073
    • Release Date:2018/08/22 16:25
  • FR-A800

    Number of terminals: There are the same output terminals as A700 and the following terminals (2 points) are added. Safety: SO, SOC * The terminals SO and SOC... More Details >>

    • No:21098
    • Release Date:2018/08/22 16:25
  • PLC function

    No. To set the PLC function, FR Configurator2 is required. (However, the setting cannot be configured with the trial version.) More Details >>

    • No:21102
    • Release Date:2018/08/22 16:25
  • Frequency search of the FR-A800/FR-F800

    DC voltage is applied when Pr.162 = 0, and AC voltage is applied when Pr.162 = 3 or 13. For the AC, the operation is easier to continue than the DC and the i... More Details >>

    • No:20831
    • Release Date:2018/08/22 16:24
  • Built-in PLC function

    The error indicates that the parameter setting of the PLC function is not set. It is considered that the PC parameter is not checked when the PC parameter an... More Details >>

    • No:20859
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    The direct connection with the inverter like the standard model, and the connection via the GOT and relay station (programmable controller) are available. On... More Details >>

    • No:20879
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    Yes, it can like the standard product. More Details >>

    • No:20880
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    There are some restrictions compared to the FR-A800 (RS-485 communication type). For example, the FR-A8TR is unavailable, and only two option connectors are ... More Details >>

    • No:20884
    • Release Date:2018/08/22 16:24