FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A800
FAQ
Keyword Search
FAQ within [ FREQROL-A800 ]
-
This error occurs when the parameter file is broken. More Details >>
- No:20937
- Release Date:2018/08/22 16:25
-
It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>
- No:20839
- Release Date:2018/08/22 16:24
-
Frequency search of the FR-A800/FR-F800
DC voltage is applied when Pr.162 = 0, and AC voltage is applied when Pr.162 = 3 or 13. For the AC, the operation is easier to continue than the DC and the i... More Details >>
- No:20831
- Release Date:2018/08/22 16:24
-
Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>
- No:20904
- Release Date:2018/08/22 16:25
-
Europe EMC Directive compliance
By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>
- No:21116
- Release Date:2018/08/22 16:26
-
No. To set the PLC function, FR Configurator2 is required. (However, the setting cannot be configured with the trial version.) More Details >>
- No:21102
- Release Date:2018/08/22 16:25
-
The number of timer points is 16 for the high speed and low speed in total. More Details >>
- No:21056
- Release Date:2018/08/22 16:25
-
The gain of the tension PI gain automatic tuning is the one of the dancer feedback speed control. The gain adjusted by speed control P gain compensation is t... More Details >>
- No:20925
- Release Date:2018/08/22 16:25
-
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
- No:20905
- Release Date:2018/08/22 16:25
-
Yes, they can. More Details >>
- No:20856
- Release Date:2018/08/22 16:24
81-90 of Total 142