FAQ
FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A800
FAQ
Keyword Search
FAQ within [ FREQROL-A800 ]
-
Yes, it does. (There are some restrictions. More Details >>
- No:21082
- Release Date:2018/08/22 16:25
-
When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>
- No:21073
- Release Date:2018/08/22 16:25
-
Basically, it depends on machine specifications. Advantage of dancer feedback speed control: Easy control. Small tension can be controlled. Disadvantage: Mac... More Details >>
- No:20973
- Release Date:2018/08/22 16:25
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
-
Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>
- No:20904
- Release Date:2018/08/22 16:25
-
The RJ-45 compatible connector (LAN cable), switching hub, and others are required The auto detection of the connection devices, externally monitoring the in... More Details >>
- No:20882
- Release Date:2018/08/22 16:24
-
By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>
- No:21106
- Release Date:2018/08/22 16:25
-
The processing speed, scan time, and others are slower than those of the programmable controllers. There are some restrictions in the number of I/O points, p... More Details >>
- No:21103
- Release Date:2018/08/22 16:25
-
Power is supplied only to the control power supply, and thus this enables communication, parameter setting through the operation panel or an USB memory devic... More Details >>
- No:21097
- Release Date:2018/08/22 16:25
-
Installation necessity of a DC reactor
A DC reactor connection is required under the following conditions. - Inverter capacity is 75K or higher - Motor capacity is 75 kW or higher. If any of the a... More Details >>
- No:21077
- Release Date:2018/08/22 16:25