  • Gain adjustment under the speed control

    Since the lower limit has been internally set, 3% or less is recognized as 3%. More Details >>

    • No:21016
    • Release Date:2018/08/22 16:25
  • Parameter copy to the USB memory

    Yes. Writing is available when the power supply specification or capacity is different. Note that setting values of the voltage relation is also overwritten ... More Details >>

    • No:21013
    • Release Date:2018/08/22 16:25
  • 24 VDC power supply

    Power is supplied only to the control power supply, and thus this enables communication, parameter setting through the operation panel or an USB memory devic... More Details >>

    • No:21097
    • Release Date:2018/08/22 16:25
  • PLC function

    When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>

    • No:21073
    • Release Date:2018/08/22 16:25
  • FR-A8TAT

    The output of the FM terminal becomes the current output of the CA. More Details >>

    • No:21060
    • Release Date:2018/08/22 16:25
  • FR-A800-CRN

    The inverter with circuit board coating (conforming to IEC60721-3-3 3C2/3S2) ensures reliability even in poor environments. Furthermore, the inverter with pl... More Details >>

    • No:20975
    • Release Date:2018/08/22 16:25
  • Anti-sway control

    Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>

    • No:20953
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>

    • No:20923
    • Release Date:2018/08/22 16:25
  • FR-A800-R2R

    Yes. It can be carried out like under the dancer feedback speed control. More Details >>

    • No:20885
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    When it is required to keep the safety of the inverter and the system against unauthorized access from external devices via the network, take countermeasures... More Details >>

    • No:20883
    • Release Date:2018/08/22 16:24