  • FR-F800

    Yes, the current is limited under the PM sensorless control. More Details >>

    • No:20936
    • Release Date:2018/08/22 16:25
  • EMC filter

    A capacitive filter and common mode choke are built in. (A common mode choke is built in only for the 55K or lower.) Use a connector for whether to turn ON o... More Details >>

    • No:21094
    • Release Date:2018/08/22 16:25
  • Europe EMC Directive compliance

    By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>

    • No:21116
    • Release Date:2018/08/22 16:26
  • Carrier frequency automatic reducing function

    The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>

    • No:20903
    • Release Date:2018/08/22 16:25
  • PM motor control

    For the FR-F700P, only dedicated IPM motor (MM-EFS, MM-THE4) can be driven. For the FR-F800, the name is different because PM motors manufactured by other co... More Details >>

    • No:21061
    • Release Date:2018/08/22 16:25
  • Optimum excitation control

    For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>

    • No:21072
    • Release Date:2018/08/22 16:25
  • Offline auto tuning

    Under Advanced magnetic flux vector control or PM motor control, measuring motor constants automatically enables optimal operation of motors even when motor ... More Details >>

    • No:21071
    • Release Date:2018/08/22 16:25
  • FR-F800

    No, it isn't. Use the multiple rating (LD, SLD) of the FR-A800. More Details >>

    • No:20972
    • Release Date:2018/08/22 16:25
  • Built-in PLC function

    The error indicates that the parameter setting of the PLC function is not set. It is considered that the PC parameter is not checked when the PC parameter an... More Details >>

    • No:20859
    • Release Date:2018/08/22 16:24
  • Simple magnetic flux vector control

    The simple magnetic flux vector control is unavailable for the FR-F800. The advanced magnetic flux vector control is higher-level function of the simple magn... More Details >>

    • No:21058
    • Release Date:2018/08/22 16:25