  • Life measurement of the main circuit capacitor

    No. Turn OFF and ON both main circuit and control circuit. More Details >>

    • No:20999
    • Release Date:2018/08/22 16:25
  • PLC function

    The number of timer points is 16 for the high speed and low speed in total. More Details >>

    • No:21056
    • Release Date:2018/08/22 16:25
  • USB version

    Ver1.1 (Ver2.0 (full speed) compatible). USB1.1 supports Full Speed (12 Mbps) and Low Speed (1.5 Mbps) transmission speed modes. USB2.0 supports High Speed (... More Details >>

    • No:21096
    • Release Date:2018/08/22 16:25
  • Combination of the FR-F800 and MM-EFS

    Yes, it can. Set "12" or "112" to the MM-EFS capacity used for Pr.80 (Motor capacity) and Pr.998 (PM parameter initialization). More Details >>

    • No:20820
    • Release Date:2018/08/22 16:24
  • Combination of the FR-F800 and FR-A8TAT

    Yes, it can. For the capacity of 37K or more, use the included bracket for installation. More Details >>

    • No:20841
    • Release Date:2018/08/22 16:24
  • CC-Link IE Field Basic

    Up to 64 (slave stations). The number of connectable units differs depending on the master station. More Details >>

    • No:20857
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    There are some restrictions compared to the FR-A800 (RS-485 communication type). For example, the FR-A8TR is unavailable, and only two option connectors are ... More Details >>

    • No:20884
    • Release Date:2018/08/22 16:24
  • Load characteristics fault detection

    Only the V/F control is related with Pr.56. The motor torque is calculated from the current value (not Pr.56) and motor constant. For the V/F control, it is ... More Details >>

    • No:20893
    • Release Date:2018/08/22 16:24
  • Control power supply

    Turning ON the main circuit power stops the 24 V external power supply operation and enables the normal operation. Therefore, the separate power supply canno... More Details >>

    • No:21018
    • Release Date:2018/08/22 16:25
  • The number of output terminals

    The number of terminals: There are the same output terminals as F700P and the following terminals (2 points) are added. Safety: SO, SOC *The terminals SO and... More Details >>

    • No:21069
    • Release Date:2018/08/22 16:25