FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-F800
FAQ
Keyword Search
FAQ within [ FREQROL-F800 ]
-
By setting the operating condition, such as load level and surrounding air temperature, according to the application, the inverter capacity may be lowered co... More Details >>
- No:21101
- Release Date:2018/08/22 16:25
-
Europe EMC Directive compliance
By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>
- No:21116
- Release Date:2018/08/22 16:26
-
The number of timer points is 16 for the high speed and low speed in total. More Details >>
- No:21056
- Release Date:2018/08/22 16:25
-
The number of output terminals
The number of terminals: There are the same output terminals as F700P and the following terminals (2 points) are added. Safety: SO, SOC *The terminals SO and... More Details >>
- No:21069
- Release Date:2018/08/22 16:25
-
Power supply harmonics countermeasure
Use a high power factor converter FR-HC2 or reactor as needed. More Details >>
- No:21115
- Release Date:2018/08/22 16:26
-
The RJ-45 compatible connector (LAN cable), switching hub, and others are required The auto detection of the connection devices, externally monitoring the in... More Details >>
- No:20882
- Release Date:2018/08/22 16:24
-
It is 2 to 3 ms. By setting Pr.289 Inverter output terminal filter and Pr.699 Input terminal filter, the FR-A700 can be compatible with the response of the t... More Details >>
- No:20899
- Release Date:2018/08/22 16:24
-
Residual voltage at the output shutoff
The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>
- No:20906
- Release Date:2018/08/22 16:25
-
Communication specifications for connection of multiple inverters
Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>
- No:20998
- Release Date:2018/08/22 16:25
-
They can be compliant by connecting an optional DC reactor (FR-HEL). (A capacitive filter and common mode choke are built in (the common mode choke is provid... More Details >>
- No:21117
- Release Date:2018/08/22 16:26
21-30 of Total 89