  • Setting values of the FR-F800 when replaced with the FR-F400

    The performance and noise countermeasure were improved and the initial value is set to "8". Try with the initial value "2" first. If the noise is distracting... More Details >>

    • No:20808
    • Release Date:2018/08/22 16:24
  • Plug-in options

    The conventional plug-in option (FR-A7[][]) cannot be used. Use the dedicated plug-in option (FR-A8[][]). More Details >>

    • No:21114
    • Release Date:2018/08/22 16:25
  • Operation panel

    If the operation panel has not been operated for the time set in Pr.1048 Display-off waiting time, the display-off mode is enabled and the "MON" LED blinks s... More Details >>

    • No:21075
    • Release Date:2018/08/22 16:25
  • PLC function

    The setting is enabled at the Y24 start-up. The frequency cannot be changed when Y24 is always ON. Turn ON Y24 when writing a frequency. More Details >>

    • No:21048
    • Release Date:2018/08/22 16:25
  • PLC function

    Vector control: The SM1217 turns ON when the motor rotates even if no forward rotation command is send. Other than vector control: The SM1217 turn ON by forw... More Details >>

    • No:20907
    • Release Date:2018/08/22 16:25
  • Residual voltage at the output shutoff

    The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>

    • No:20906
    • Release Date:2018/08/22 16:25
  • FR-A800-E

    When it is required to keep the safety of the inverter and the system against unauthorized access from external devices via the network, take countermeasures... More Details >>

    • No:20883
    • Release Date:2018/08/22 16:24
  • FR-A800-E

    The RJ-45 compatible connector (LAN cable), switching hub, and others are required The auto detection of the connection devices, externally monitoring the in... More Details >>

    • No:20882
    • Release Date:2018/08/22 16:24
  • FR-A800

    No, they do not. Pr.72 is invalid at the offline auto tuning. It is also invalid when the motor rotates with Pr.96 = 101. More Details >>

    • No:20878
    • Release Date:2018/08/22 16:24
  • CC-Link IE Field Basic

    Up to 64 (slave stations). The number of connectable units differs depending on the master station. More Details >>

    • No:20857
    • Release Date:2018/08/22 16:24