Parameter copy to the USB memory
Yes. Parameters can be read except during an inverter reset or when the password function is set. More Details >>
The storage areas for the sequence programs and for the parameters of the inverter are different. More Details >>
The country in which the product is manufactured is described on the rating plate as MADE IN JAPAN or MADE IN CHINA. More Details >>
This error occurs when the parameter file is broken. More Details >>
Yes, the current is limited under the PM sensorless control. More Details >>
Vector control: The SM1217 turns ON when the motor rotates even if no forward rotation command is send. Other than vector control: The SM1217 turn ON by forw... More Details >>
Residual voltage at the output shutoff
The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>
Carrier frequency automatic reducing ...
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>