  • Optimum excitation control

    For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>

    • No:21072
    • Release Date:2018/08/22 16:25
  • FR-F800

    No, it isn't. Use the multiple rating (LD, SLD) of the FR-A800. More Details >>

    • No:20972
    • Release Date:2018/08/22 16:25
  • Europe EMC Directive compliance

    By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>

    • No:21116
    • Release Date:2018/08/22 16:26
  • Load characteristics fault detection

    Only the V/F control is related with Pr.56. The motor torque is calculated from the current value (not Pr.56) and motor constant. For the V/F control, it is ... More Details >>

    • No:20893
    • Release Date:2018/08/22 16:24
  • Simple magnetic flux vector control

    The simple magnetic flux vector control is unavailable for the FR-F800. The advanced magnetic flux vector control is higher-level function of the simple magn... More Details >>

    • No:21058
    • Release Date:2018/08/22 16:25
  • The number of input terminals

    The number of terminals: There are the same input terminals as F700P and the following terminals (4 points) are added. Safety: SI1, SI2, SIC 24 V power suppl... More Details >>

    • No:21070
    • Release Date:2018/08/22 16:25
  • FR-F800

    Yes, the current is limited under the PM sensorless control. More Details >>

    • No:20936
    • Release Date:2018/08/22 16:25
  • Error at USB parameter copy

    This error occurs when the parameter file is broken. More Details >>

    • No:20937
    • Release Date:2018/08/22 16:25
  • PLC function

    SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>

    • No:21057
    • Release Date:2018/08/22 16:25
  • The number of output terminals

    The number of terminals: There are the same output terminals as F700P and the following terminals (2 points) are added. Safety: SO, SOC *The terminals SO and... More Details >>

    • No:21069
    • Release Date:2018/08/22 16:25