  • FR-HC2

    Do not carry out a pressure test. As for a megger test, carry out the test with 500 VDC as describes in the Instruction Manual of the inverter. More Details >>

    • No:20967
    • Release Date:2018/08/22 16:25
  • FR-FS2

    The description has been deleted because there is no industrial pressure ventilation fan that can be used for the FR-FS2, due to the production termination o... More Details >>

    • No:21064
    • Release Date:2018/08/22 16:25
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • How can I calculate the processing torque from the measured power?

    You can calculate the torque from the power.  From the general equation: Pout = ωn × TT = (Pout × τ)/ωnPout: Measured valueωn: Actual motor shaft angular fre... More Details >>

    • No:21475
    • Release Date:2018/08/22 16:27
  • Insulation level of the MM-EFS

    F class (155 deg C) More Details >>

    • No:20809
    • Release Date:2018/08/22 16:24
  • Selection

    It is not completely recommended to use F700P because the starting torque at low speed of the hydraulic pump may be larger than that of the normal pump. Sele... More Details >>

    • No:21126
    • Release Date:2018/08/22 16:26
  • Connection with pole change motor

    Since the inverter allows for changing speed, fix the number of poles when using the pole change motor. It is recommended to fix the number of poles to four ... More Details >>

    • No:21486
    • Release Date:2018/08/22 16:27
  • Surge voltage of 400 V inverter

    1. Since the voltage resistance of the standard motor is not improved, it is recommended to use an "insulation-enhanced motor".If you are using an insulation... More Details >>

    • No:21957
    • Release Date:2018/08/22 16:30
  • Can you provide the CAD data?

    The CAD data is found on the member's page of Mitsubishi Electric FA Global Website. More Details >>

    • No:22091
    • Release Date:2018/08/22 16:30
  • MM-CF

    DC90V More Details >>

    • No:20965
    • Release Date:2018/08/22 16:25