  • MM-EF/EFS

    Yes, the 7.5 kW or lower motor can be used for belt drive hanging and direct connection. Note that the standard models of 11 kW or higher motor are dedicated... More Details >>

    • No:20962
    • Release Date:2018/08/22 16:25
  • FR-B/FR-B3

    Yes. More Details >>

    • No:21063
    • Release Date:2018/08/22 16:25
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • Inverter circuit breaker selection

    Since the inverter leakage current is in proportion to the switching voltage of the transistor of the main circuit, the leakage current for the 400 V system ... More Details >>

    • No:21429
    • Release Date:2018/08/22 16:27
  • How can I calculate the processing torque from the measured power?

    You can calculate the torque from the power.  From the general equation: Pout = ωn × TT = (Pout × τ)/ωnPout: Measured valueωn: Actual motor shaft angular fre... More Details >>

    • No:21475
    • Release Date:2018/08/22 16:27
  • Energy saving and power supply capacity of inverter

    Energy saving is achieved by switching from the commercial power supply to the inverter to operate the motor. When the inverter reduces motor speed, it also... More Details >>

    • No:21498
    • Release Date:2018/08/22 16:27
  • Countermeasure against noise on input side

    In general, the line noise filter (FR-BLF) is used against the power supply noise. The AC reactor also works. As other countermeasures:- Use a metal conduit ... More Details >>

    • No:21517
    • Release Date:2018/08/22 16:28
  • No load current value of motor

    No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>

    • No:21534
    • Release Date:2018/08/22 16:28
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28