  • Selection

    It is not completely recommended to use F700P because the starting torque at low speed of the hydraulic pump may be larger than that of the normal pump. Sele... More Details >>

    • No:21126
    • Release Date:2018/08/22 16:26
  • Instruction manual

    PDF data is available free of charge with free registration from the Mitsubishi Electric FA Global Website. All the printed materials are available for a fee. More Details >>

    • No:21127
    • Release Date:2018/08/22 16:26
  • CAD data

    They are not available. More Details >>

    • No:21138
    • Release Date:2018/08/22 16:26
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • Compatibility with Y-△ motor and others

    1. You can connect them using △ connection. 2. No problem with connecting four Y-△ motors. (Connect all four motors using △ connection.) (Note that the inver... More Details >>

    • No:21487
    • Release Date:2018/08/22 16:27
  • Number of years of service life designated by law

    The number of years of service life of the inverter is not designated by law. More Details >>

    • No:21497
    • Release Date:2018/08/22 16:27
  • Acquisition of pressure-resistant explosion-proof certification

    The test institutes assigned by the Minister of Health, Labour and Welfare (National Institute of Occupational Safety and Health and Technology Institution o... More Details >>

    • No:21510
    • Release Date:2018/08/22 16:28
  • Communication option

    You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>

    • No:21625
    • Release Date:2018/08/22 16:28