  • Influence on external measurement device

    It is considered that malfunction of the measurement device is due to noise. Check the noise propagation route since the countermeasure depends on it. Some c... More Details >>

    • No:22100
    • Release Date:2018/08/22 16:30
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • Insulation level of the MM-EFS

    F class (155 deg C) More Details >>

    • No:20809
    • Release Date:2018/08/22 16:24
  • Countermeasure against inverter noise

    You can attach the following filters to the inverter input side:- Line noise filter (FR-BLF, FR-BSF01)- Radio noise filter (FR-BIF)  While it is a good idea ... More Details >>

    • No:21528
    • Release Date:2018/08/22 16:28
  • Surge voltage of 400 V inverter

    1. Since the voltage resistance of the standard motor is not improved, it is recommended to use an "insulation-enhanced motor".If you are using an insulation... More Details >>

    • No:21957
    • Release Date:2018/08/22 16:30
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • MM-EF/EFS

    Since the standard bearing is adopted for the belt drive models, a creep may occur and the motor bracket may wear out. More Details >>

    • No:20964
    • Release Date:2018/08/22 16:25
  • CAD data

    They are not available. More Details >>

    • No:21138
    • Release Date:2018/08/22 16:26
  • Parameter list

    The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>

    • No:21485
    • Release Date:2018/08/22 16:27
  • No load current value of motor

    No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>

    • No:21534