Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-E700 ]

101-110 of Total 394

prev 11 / 40page next
  • CC-Link

    Connect the wire to the optional FR-A7NC's terminal block. (The terminal block is detachable.) More Details >>

    • No:21875
    • Release Date:2018/08/22 16:29
  • Start command, speed command

    You can do so by setting Pr.339 (Communication speed command source) = 1 (external).   More Details >>

    • No:21881
    • Release Date:2018/08/22 16:29
  • Frequency

    Keep Y100D turned ON if you are changing the frequency continuously.  More Details >>

    • No:21883
    • Release Date:2018/08/22 16:29
  • CC-Link

    You can select from the output power (in 0.01 kW units) and cumulative energy (in 1 kWh/0.01 kWh units). More Details >>

    • No:21885
    • Release Date:2018/08/22 16:29
  • CC-Link

    Yes. The FR-A7NC E kit contains a dedicated front cover since its size changes by the installed board.You can additionally purchase the FR-A7NC E kit cover o... More Details >>

    • No:21889
    • Release Date:2018/08/22 16:29
  • CC-Link

    No problem. The inverter actually occupies the reserved bits and does not use them. More Details >>

    • No:21890
    • Release Date:2018/08/22 16:29
  • CC-Link

    Check if the CC-Link wires are short-circuited and/or station numbers are duplicated.   More Details >>

    • No:21891
    • Release Date:2018/08/22 16:29
  • CC-Link

    You can select deceleration stop by setting Pr.502 (Stop mode selection at communication error). (Select from coasting to stop, deceleration to stop, and con... More Details >>

    • No:21892
    • Release Date:2018/08/22 16:29
  • CC-Link

    We provide FR-E720-□KNC that is the CC-Link built-in model. More Details >>

    • No:21893
    • Release Date:2018/08/22 16:29
  • CC-Link, analog output card

    You can install only one option card.If you want to use two types of cards, replace the inverter with the FR-A700 series.If you can use RS485 communication i... More Details >>

    • No:21894
    • Release Date:2018/08/22 16:29

101-110 of Total 394