Up to 30 m. (To avoid noise and voltage drop) More Details >>
- No:21910
- Release Date:2018/08/22 16:30
-
No. Use a frequency setting potentiometer with the resistance of 1 kΩ and B characteristics.Input voltage is not linear due to the inverter's internal impeda... More Details >>
- No:21911
- Release Date:2018/08/22 16:30
-
Use the setting dial to set the frequency with the FR-E700.You can also use the setting dial to set the parameters.(By setting Pr.161, you can use the settin... More Details >>
- No:21918
- Release Date:2018/08/22 16:30
-
Circuit type of the FR-D700W/FR-E700W in the harmonics suppression guideline
It is single-phase bridge (smoothing capacitor, double voltage rectification). More Details >>
- No:20864
- Release Date:2018/08/22 16:24
-
The length within 30 m is recommended. When the wiring length is long, signals may not be received accurately due to the increased inductance. More Details >>
- No:20995
- Release Date:2018/08/22 16:25
-
If Pr 27 is not set, the operation starts at the speed of RL. More Details >>
- No:21123
- Release Date:2018/08/22 16:26
-
Reverse rotation prevention selection
Yes, it does. When the inverter is coasting in the reverse direction, it starts in the reverse direction and switches to the forward rotation after a deceler... More Details >>
- No:21125
- Release Date:2018/08/22 16:26
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
-
The total wiring length is as follows: 100 m + (20 m × 5) = 200m. More Details >>
- No:21144
- Release Date:2018/08/22 16:26
-
Set Pr.71 (Applied motor), Pr.80 (Motor capacity), Pr.81 (Number of motor poles), and Pr.800 (Control method selection). More Details >>