FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL > FREQROL-E700
FAQ
Keyword Search
FAQ within [ FREQROL-E700 ]
-
No, it cannot. More Details >>
- No:21253
- Release Date:2018/08/22 16:26
-
After setting Pr.79 (Operation mode selection) to "2" and Pr.340 (Communication startup mode selection) to "10", reset the inverter (or power ON again) to st... More Details >>
- No:21256
- Release Date:2018/08/22 16:26
-
By setting Pr.160 (User group read selection ("Extended function display selection" for D700)) to "0", all the parameters can be read. More Details >>
- No:21262
- Release Date:2018/08/22 16:26
-
Real sensorless vector control
No, Real sensorless vector control cannot be used in the FR-E700. More Details >>
- No:21269
- Release Date:2018/08/22 16:26
-
The ferrule terminal or single wire can be used for the control circuit wiring. More Details >>
- No:21275
- Release Date:2018/08/22 16:26
-
The detection time 1 s cannot be changed. More Details >>
- No:21277
- Release Date:2018/08/22 16:26
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
-
When the torque is supposed as 100% at 60 Hz, the torque becomes 75 % at 80 Hz. (Under V/F control, the torque decreases when the frequency exceeds 60 Hz bec... More Details >>
- No:21284
- Release Date:2018/08/22 16:26
-
Horizontal installation prevents heat release, resulting in a failure. Install the inverter vertically. More Details >>
- No:21286
- Release Date:2018/08/22 16:26
-
Use the digital output/additional analog output FR-A7AY (E kit). More Details >>
- No:21290
- Release Date:2018/08/22 16:26
11-20 of Total 394