Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-E700 ]

11-20 of Total 393

prev 2 / 40page next
  • Frequency setting

    Since Advanced magnetic flux vector control is chosen, the inverter calculates how much the motor rotation slips from the flowing current and adds the slip a... More Details >>

    • No:21684
    • Release Date:2018/08/22 16:28
  • FR-E740

    The following is the amount of heat generated for each capacity:0.4K: 40W  0.75K: 55W  1.5K: 90W  2.2K: 100W3.7K: 180W  5.5K: 240W  7.5K: 300W  11K: 400W15K:... More Details >>

    • No:21705
    • Release Date:2018/08/22 16:29
  • FR-E720

    The following is the amount of heat generated for each capacity:0.1K: 14W  0.2K: 20W  0.4K: 32W  0.75K: 50W1.5K: 80W  2.2K: 100W  3.7K: 160W  5.5K: 290W7.5K:... More Details >>

    • No:21706
    • Release Date:2018/08/22 16:29
  • Parameter setting

    You can perform forward and reverse operations with the RUN key on the operation panel by setting Pr.40 (RUN key rotation direction selection). More Details >>

    • No:21719
    • Release Date:2018/08/22 16:29
  • Electromagnetic contactor

    It cannot be avoided by using parameters.   More Details >>

    • No:21724
    • Release Date:2018/08/22 16:29
  • Electromagnetic contactor

    Turning ON/OFF the output side during operation causes open/close surges that may trigger the protective function (against overcurrent or overvoltage) of the... More Details >>

    • No:21725
    • Release Date:2018/08/22 16:29
  • Frequency setting

    You need to press the "SET" key with the initial setting.The frequency is not set unless you press the "SET" key.Setting Pr.161 (Frequency setting/key lock o... More Details >>

    • No:21735
    • Release Date:2018/08/22 16:29
  • Current setting

    Yes.The parameters used when the terminal 4 is used are C5, C6, 126, and C7.Set Pr.C5 (Terminal 4 frequency setting bias frequency) while feeding a current s... More Details >>

    • No:21770
    • Release Date:2018/08/22 16:29
  • Operation mode setting value

    Set Pr.79 to "2" (external operation mode).    More Details >>

    • No:21818
    • Release Date:2018/08/22 16:29
  • CC-Link

    By attaching the optional card and dedicated cover, the depth increases by approximately 15 mm for the FR-E700, and approximately 22 mm for the FR-E700-SC.Si... More Details >>