  • FR-BU2

    You cannot use the brake unit FR-BU2 with the FR-E740-1.5K. To use the brake unit, increase the inverter capacity to 2.2K. You can use the brake unit with th... More Details >>

    • No:21665
    • Release Date:2018/08/22 16:28
  • Parameter setting

    Set Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96.   More Details >>

    • No:21721
    • Release Date:2018/08/22 16:29
  • Rated motor current setting

    No. the torque cannot be limited by using Pr.9.Set Pr.277 (Stall prevention current switching) to "1".The value of Pr.22 (Stall prevention operation level) w... More Details >>

    • No:21766
    • Release Date:2018/08/22 16:29
  • Output frequency monitor value

    When running the inverter after auto tuning, the frequency setting value is increased by the amount of the motor slippage, resulting in a higher monitor valu... More Details >>

    • No:21781
    • Release Date:2018/08/22 16:29
  • Frequency setting

    Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>

    • No:21807
    • Release Date:2018/08/22 16:29
  • CC-Link

    Did you purchase the FR-A7NC?If the front cover is supplied with the FR-A7NC E kit, it will fit. More Details >>

    • No:21895
    • Release Date:2018/08/22 16:29
  • CC-Link

    Set Pr.550 (NET mode operation command source selection) to "2" (PU connector is the command source).When operating the inverter using the USB connector, set... More Details >>

    • No:21904
    • Release Date:2018/08/22 16:30
  • FR-E700-KNC

    They are not insulated. More Details >>

    • No:21163
    • Release Date:2018/08/22 16:26
  • Offline auto tuning

    Leave the setting of Pr.96 as "3". It indicates that auto tuning has been completed and the motor constant has been read. When it is changed unnecessarily, t... More Details >>

    • No:21352
    • Release Date:2018/08/22 16:27
  • Analog voltage

    Check the setting value of Pr.73. Or check Pr.C4 (Terminal 2 frequency setting gain) for the percentage of the voltage that is actually applied. For the FR-E... More Details >>

    • No:21356
    • Release Date:2018/08/22 16:27