FAQ within [ FREQROL-E700 ]

21-30 of Total 394

prev 3 / 40page next
  • FR-BU2

    You cannot use the brake unit FR-BU2 with the FR-E740-1.5K. To use the brake unit, increase the inverter capacity to 2.2K. You can use the brake unit with th... More Details >>

    • No:21665
    • Release Date:2018/08/22 16:28
  • English manual

    On the Mitsubishi Electric FA Global Website, choose "Inverter FREQROL", "Manual", and "FREQROL-E700", and change the language to "English". More Details >>

    • No:21666
    • Release Date:2018/08/22 16:28
  • Frequency setting

    Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>

    • No:21807
    • Release Date:2018/08/22 16:29
  • Terminal assignment

    The terminal MRS assignment parameter is Pr.183. Set Pr.183 to "4" (AU). (This setting is for the E700.) More Details >>

    • No:21850
    • Release Date:2018/08/22 16:29
  • CC-Link

    We provide FR-E720-□KNC that is the CC-Link built-in model. More Details >>

    • No:21893
    • Release Date:2018/08/22 16:29
  • CC-Link, analog output card

    You can install only one option card.If you want to use two types of cards, replace the inverter with the FR-A700 series.If you can use RS485 communication i... More Details >>

    • No:21894
    • Release Date:2018/08/22 16:29
  • FR-E720S-KNC

    It is available on request. More Details >>

    • No:21164
    • Release Date:2018/08/22 16:26
  • FR-E720S-NC

    It is available on request as a dedicated product. Contact your sales representative. More Details >>

    • No:21183
    • Release Date:2018/08/22 16:26
  • Real sensorless vector control

    No, Real sensorless vector control cannot be used in the FR-E700. More Details >>

    • No:21269
    • Release Date:2018/08/22 16:26
  • Specifications

    It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>

    • No:21282
    • Release Date:2018/08/22 16:26