No. The "RUN" key on the FR-PA07 does not work.The start command is accepted from the external source. More Details >>
- No:21703
- Release Date:2018/08/22 16:29
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
-
Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>
- No:21807
- Release Date:2018/08/22 16:29
-
When offline auto tuning ends normally, the setting of this parameter changes to "3".This means that auto tuning completed normally.If the setting value is "... More Details >>
- No:21748
- Release Date:2018/08/22 16:29
-
Connecting it causes no problem. More Details >>
- No:21671
- Release Date:2018/08/22 16:28
-
Since the operation panel and PU connector cannot be specified for command source at the same time, they cannot be used together. More Details >>
- No:21349
- Release Date:2018/08/22 16:27
-
When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>
- No:21801
- Release Date:2018/08/22 16:29
-
Yes. More Details >>
- No:21749
- Release Date:2018/08/22 16:29
-
Set Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96. More Details >>
- No:21721
- Release Date:2018/08/22 16:29
-
There is a priority between the setting dial and multi-speed settings.Since the multi-speed setting is given a higher priority, the setting by the setting di... More Details >>
- No:21702
- Release Date:2018/08/22 16:29