  • Running frequency, output current

    Since the FR-E700 has only one terminal FM, you cannot read two signals simultaneously.Use the optional digital output/additional analog output FR-A7AY.This ... More Details >>

    • No:21822
    • Release Date:2018/08/22 16:29
  • FR-E740

    The following is the amount of heat generated for each capacity:0.4K: 40W  0.75K: 55W  1.5K: 90W  2.2K: 100W3.7K: 180W  5.5K: 240W  7.5K: 300W  11K: 400W15K:... More Details >>

    • No:21705
    • Release Date:2018/08/22 16:29
  • FR-E700

    The operation panel of the FR-E700 is not detachable because it is integrated.The operation panel of the FR-E500 can be used with the FR-E700 by using the co... More Details >>

    • No:21857
    • Release Date:2018/08/22 16:29
  • FR-E720

    The following is the amount of heat generated for each capacity:0.1K: 14W  0.2K: 20W  0.4K: 32W  0.75K: 50W1.5K: 80W  2.2K: 100W  3.7K: 160W  5.5K: 290W7.5K:... More Details >>

    • No:21706
    • Release Date:2018/08/22 16:29
  • Analog voltage

    Check the setting value of Pr.73. Or check Pr.C4 (Terminal 2 frequency setting gain) for the percentage of the voltage that is actually applied. For the FR-E... More Details >>

    • No:21356
    • Release Date:2018/08/22 16:27
  • Advanced magnetic flux vector control

    It can be used with the FR-A700 and FR-E700 series. More Details >>

    • No:21298
    • Release Date:2018/08/22 16:26
  • CC-Link

    Set Pr.550 (NET mode operation command source selection) to "2" (PU connector is the command source).When operating the inverter using the USB connector, set... More Details >>

    • No:21904
    • Release Date:2018/08/22 16:30
  • FR-E710W

    Yes. The model is FR-E710W. The input is single-phase 100 V, but the output is three-phase 200 V. More Details >>

    • No:21320
    • Release Date:2018/08/22 16:27
  • FR-E700

    Use Pr.C24 (Frequency setting voltage gain frequency built-in potentiometer). More Details >>