FAQ within [ FREQROL-E700 ]
-
Advanced magnetic flux vector control
Set "13" in Pr.71. Always perform auto tuning. More Details >>
- No:21299
- Release Date:2018/08/22 16:26
-
With the monitor indicator "1", there is no problem with the parameter setting of auto tuning. Check if the terminals MRS and SD are not shortened in the wir... More Details >>
- No:21294
- Release Date:2018/08/22 16:26
-
Even though the maximum frequency setting is changed using CC-Link, the running frequency is not changed. By writing the set frequency to the remote register... More Details >>
- No:21346
- Release Date:2018/08/22 16:27
-
The USB connection requires FR Configurator (FR-SW3-SETUP-WJ) prepared by Mitsubishi Electric Corporation. More Details >>
- No:21318
- Release Date:2018/08/22 16:27
-
Use the digital output/additional analog output FR-A7AY (E kit). More Details >>
- No:21290
- Release Date:2018/08/22 16:26
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
-
Yes. It is available by using the FR-A7AY (plug-in option). By setting Pr.307 (Setting for zero analog output) to "20" and Pr.309 (Analog output signal volta... More Details >>
- No:21246
- Release Date:2018/08/22 16:26
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
-
Stop-on-contact control of the FR-E700
The stop-on-contact control becomes invalid when the start command is turned OFF during the stop-on-contact control and the machine is decelerated to a stop ... More Details >>
- No:20822
- Release Date:2018/08/22 16:24
-
It is available since November, 2007. The model is FR-A7ND E kit. More Details >>
- No:21321
- Release Date:2018/08/22 16:27