  • Frequency setting

    Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>

    • No:21807
    • Release Date:2018/08/22 16:29
  • FR-Configurator

    No. You cannot connect it to multiple inverters.You can only connect a single personal computer to a single inverter via USB. More Details >>

    • No:21710
    • Release Date:2018/08/22 16:29
  • FR-E700

    Use Pr.C24 (Frequency setting voltage gain frequency built-in potentiometer). More Details >>

    • No:21847
    • Release Date:2018/08/22 16:29
  • FR-E700KNC

    The inverter is reset. More Details >>

    • No:20869
    • Release Date:2018/08/22 16:24
  • Frequency setting

    Use the setting dial to set the frequency with the FR-E700.You can also use the setting dial to set the parameters.(By setting Pr.161, you can use the settin... More Details >>

    • No:21918
    • Release Date:2018/08/22 16:30
  • Noise filter

    The noise filter is not built-in the FR-E700 series. It is built in the FR-A700/F700 series with the 55K or lower capacity. More Details >>

    • No:21276
    • Release Date:2018/08/22 16:26
  • Brake unit

    The brake unit operates when the bus voltage exceeds the brake operation voltage. More Details >>

    • No:21272
    • Release Date:2018/08/22 16:26
  • CC-Link, analog output card

    You can install only one option card.If you want to use two types of cards, replace the inverter with the FR-A700 series.If you can use RS485 communication i... More Details >>

    • No:21894
    • Release Date:2018/08/22 16:29
  • FR-E740

    The following is the amount of heat generated for each capacity:0.4K: 40W  0.75K: 55W  1.5K: 90W  2.2K: 100W3.7K: 180W  5.5K: 240W  7.5K: 300W  11K: 400W15K:... More Details >>

    • No:21705
    • Release Date:2018/08/22 16:29
  • Parameter copy

    The copy function of the parameter unit (FR-PU04) is not available. Setting each parameter again or using the convert function of FR Configurator (FR-SW3-SET... More Details >>

    • No:21337
    • Release Date:2018/08/22 16:27