  • Terminal assignment

    The terminal MRS assignment parameter is Pr.183. Set Pr.183 to "4" (AU). (This setting is for the E700.) More Details >>

    • No:21850
    • Release Date:2018/08/22 16:29
  • Single-phase 200 V input

    The FR-E720S series and D720S series conform to the single-phase 200 V input specifications. More Details >>

    • No:21723
    • Release Date:2018/08/22 16:29
  • Operation panel and FR-PA07

    Since the operation panel and PU connector cannot be specified for command source at the same time, they cannot be used together. More Details >>

    • No:21349
    • Release Date:2018/08/22 16:27
  • FR-E720

    The following is the amount of heat generated for each capacity:0.1K: 14W  0.2K: 20W  0.4K: 32W  0.75K: 50W1.5K: 80W  2.2K: 100W  3.7K: 160W  5.5K: 290W7.5K:... More Details >>

    • No:21706
    • Release Date:2018/08/22 16:29
  • FR-E700

    It is available since November, 2007. The model is FR-A7ND E kit. More Details >>

    • No:21321
    • Release Date:2018/08/22 16:27
  • Frequency setting

    When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>

    • No:21801
    • Release Date:2018/08/22 16:29
  • EMC filter

    The FR-E700 series is not equipped with the EMC filter. More Details >>

    • No:21667
    • Release Date:2018/08/22 16:28
  • Torque control

    Torque control cannot be performed with the FR-E700 series. It is available with the FR-A700 and FR-V500 series. More Details >>

    • No:21279
    • Release Date:2018/08/22 16:26
  • FR-E720S-KNC

    It is available on request. More Details >>

    • No:21164
    • Release Date:2018/08/22 16:26
  • FR-E700

    Install the DIN rail attachment to each inverter.The optional FR-A7NC is built in the inverter and does not influence installation of the inverter. More Details >>