FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-E700
FAQ
Keyword Search
FAQ within [ FREQROL-E700 ]
-
The ferrule terminal or single wire can be used for the control circuit wiring. More Details >>
- No:21275
- Release Date:2018/08/22 16:26
-
The inverter is reset. More Details >>
- No:20869
- Release Date:2018/08/22 16:24
-
Use Pr.C24 (Frequency setting voltage gain frequency built-in potentiometer). More Details >>
- No:21847
- Release Date:2018/08/22 16:29
-
Advanced magnetic flux vector control
When using the geared motor GM-S(B), set Pr.71 to "13" and also set Pr.9, Pr.80, and Pr.81.Perform auto tuning as required. Perform auto tuning as required. ... More Details >>
- No:21756
- Release Date:2018/08/22 16:29
-
The following is the amount of heat generated for each capacity:0.1K: 14W 0.2K: 20W 0.4K: 32W 0.75K: 50W1.5K: 80W 2.2K: 100W 3.7K: 160W 5.5K: 290W7.5K:... More Details >>
- No:21706
- Release Date:2018/08/22 16:29
-
Set Pr.550 (NET mode operation command source selection) to "2" (PU connector is the command source).When operating the inverter using the USB connector, set... More Details >>
- No:21904
- Release Date:2018/08/22 16:30
-
We provide FR-E720-□KNC that is the CC-Link built-in model. More Details >>
- No:21893
- Release Date:2018/08/22 16:29
-
Yes, but the optional kit (FR-A7NC E kit) is necessary. More Details >>
- No:21877
- Release Date:2018/08/22 16:29
-
The terminal MRS assignment parameter is Pr.183. Set Pr.183 to "4" (AU). (This setting is for the E700.) More Details >>
- No:21850
- Release Date:2018/08/22 16:29
-
On the Mitsubishi Electric FA Global Website, choose "Inverter FREQROL", "Manual", and "FREQROL-E700", and change the language to "English". More Details >>
- No:21666
- Release Date:2018/08/22 16:28
381-390 of Total 393