  • Safety stop function of the FR-D700/FR-E700

    It is recommended to install the magnetic contactor on the input side of the inverter for safety. The category 3 can be satisfied without installing it. More Details >>

    • No:20837
    • Release Date:2018/08/22 16:24
  • Specifications

    It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>

    • No:21282
    • Release Date:2018/08/22 16:26
  • Real sensorless vector control

    No, Real sensorless vector control cannot be used in the FR-E700. More Details >>

    • No:21269
    • Release Date:2018/08/22 16:26
  • Parameter copy

    The copy function of the parameter unit (FR-PU04) is not available. Setting each parameter again or using the convert function of FR Configurator (FR-SW3-SET... More Details >>

    • No:21337
    • Release Date:2018/08/22 16:27