  • Operation panel and FR-PA07

    Since the operation panel and PU connector cannot be specified for command source at the same time, they cannot be used together. More Details >>

    • No:21349
    • Release Date:2018/08/22 16:27
  • FR-PA07

    No. The "RUN" key on the FR-PA07 does not work.The start command is accepted from the external source. More Details >>

    • No:21703
    • Release Date:2018/08/22 16:29
  • Life diagnosis

    When Pr.259 (Main circuit capacitor life measuring) is set to "1", the life diagnosis is ready. Turning OFF the power supply starts measuring the life of the... More Details >>

    • No:21283
    • Release Date:2018/08/22 16:26
  • Replacement

    Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>

    • No:21254
    • Release Date:2018/08/22 16:26
  • Operation panel

    The operation panels of the FR-E700, FR-D700, and FR-F700PJ are not detachable.Therefore, it cannot be attached to the enclosure surface.You can use the opti... More Details >>

    • No:21851
    • Release Date:2018/08/22 16:29
  • FR-PA07

    1. Press the PU/EXT key on the operation panel FR-PA07 to choose the PU operation mode. Set Pr.161 (Frequency setting/key lock operation selection) to "1" an... More Details >>

    • No:21761
    • Release Date:2018/08/22 16:29
  • FR-PA02 built-in potentiometer

    Change Pr.146 (Built-in potentiometer switching) to "0" (built-in frequency setting potentiometer). More Details >>

    • No:21862
    • Release Date:2018/08/22 16:29
  • FR-PA07

    There is a priority between the setting dial and multi-speed settings.Since the multi-speed setting is given a higher priority, the setting by the setting di... More Details >>

    • No:21702
    • Release Date:2018/08/22 16:29
  • FR-PA07

    Only the operation command source is switched to the FR-A07 and the inverter operation panel does not turn off. (Setting from the inverter operation panel be... More Details >>

    • No:21699
    • Release Date:2018/08/22 16:28
  • Operation panel (FR-PA02)

    Set Pr.146 (Built-in potentiometer switching) to "0".This allows for using the potentiometer built in the FR-PA02 to set the frequency.(Set this parameter to... More Details >>

    • No:21730
    • Release Date:2018/08/22 16:29