  • Operation panel (FR-PA02)

    Set Pr.146 (Built-in potentiometer switching) to "0".This allows for using the potentiometer built in the FR-PA02 to set the frequency.(Set this parameter to... More Details >>

    • No:21730
    • Release Date:2018/08/22 16:29
  • Operation panel for FR-E500

    The operation panel FR-PA02 for the FR-E500 can be used for these models.You need the FR-E5P (back cover adapter set) and FR-C20□ (connection cable) for the ... More Details >>

    • No:21860
    • Release Date:2018/08/22 16:29
  • Operation panel and FR-PA07

    Since the operation panel and PU connector cannot be specified for command source at the same time, they cannot be used together. More Details >>

    • No:21349
    • Release Date:2018/08/22 16:27
  • FR-PA07

    There is a priority between the setting dial and multi-speed settings.Since the multi-speed setting is given a higher priority, the setting by the setting di... More Details >>

    • No:21702
    • Release Date:2018/08/22 16:29
  • FR-PA07

    The operation command source is automatically transferred to the connected FR-PU07 or FR-PA07. More Details >>

    • No:21700
    • Release Date:2018/08/22 16:28
  • PU operation

    Set Pr.40 (RUN key rotation direction selection) to "1" (Reverse). More Details >>

    • No:21693
    • Release Date:2018/08/22 16:28
  • FR-PA07

    Basically it is not possible due to the operation command source.However, if Pr.77 (Parameter write selection) is set to "2", you can use both the FR-PA07 an... More Details >>

    • No:21698
    • Release Date:2018/08/22 16:28
  • Parameter setting

    You can perform forward and reverse operations with the RUN key on the operation panel by setting Pr.40 (RUN key rotation direction selection). More Details >>

    • No:21719
    • Release Date:2018/08/22 16:29
  • Motor with an attached brake

    Connecting it causes no problem. More Details >>

    • No:21671
    • Release Date:2018/08/22 16:28
  • FR-PA02

    The operation panel FR-PA02 requires the optional FR-E5P (control panel rear cover and adapter set) and connection cable FR-CB20□. Check that Pr.146 (Built-i... More Details >>