  • Auto tuning

    Set "33" or "34". More Details >>

    • No:21167
    • Release Date:2018/08/22 16:26
  • Wiring length

    Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>

    • No:21133
    • Release Date:2018/08/22 16:26
  • Fast-response current limit

    It is not activated because the function itself is disabled. More Details >>

    • No:21137
    • Release Date:2018/08/22 16:26
  • FR-A701

    The AC reactor (FR-HAL) is built in the FR-A701. (The circuit type in the Harmonic Suppression Guidelines is three-phase bridge (capacitor smoothed), with re... More Details >>

    • No:21011
    • Release Date:2018/08/22 16:25
  • Input phase loss protection

    The initial value of Pr.872 is set to "1" (Valid) because the A701 have regeneration unit built-in and an overvoltage may occur when the regenerative operati... More Details >>

    • No:20945
    • Release Date:2018/08/22 16:25
  • Vector control

    They are not output while the motor is coasting even under Vector control. More Details >>

    • No:21158
    • Release Date:2018/08/22 16:26
  • Orientation control

    The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>

    • No:21162
    • Release Date:2018/08/22 16:26
  • Vector control

    "E.OSD" occurs when the rotation speed is not decreased for one second despite the start command (STF, STR) is turned OFF. More Details >>

    • No:21159
    • Release Date:2018/08/22 16:26
  • Real sensorless vector control

    The FR-A700 supports Real sensorless vector control.   More Details >>

    • No:21714
    • Release Date:2018/08/22 16:29
  • Vector control

    Install the resistor between the terminals PC and OH. More Details >>

    • No:21160
    • Release Date:2018/08/22 16:26