Yes, you can set them randomly. More Details >>
- No:21796
- Release Date:2018/08/22 16:29
-
To set the frequency via CC-Link communication, the NET mode should be selected. The new parameter setting is applied after powering OFF and then ON the inve... More Details >>
- No:21763
- Release Date:2018/08/22 16:29
-
Auto tuning can be performed because the motor is one rank lower than the inverter capacity. More Details >>
- No:21351
- Release Date:2018/08/22 16:27
-
Since the FR-PA07 has the back cover and adapter, the FR-E5P is not necessary. More Details >>
- No:21304
- Release Date:2018/08/22 16:26
-
The AC reactor (FR-HAL) is built in the FR-A701. (The circuit type in the Harmonic Suppression Guidelines is three-phase bridge (capacitor smoothed), with re... More Details >>
- No:21011
- Release Date:2018/08/22 16:25
-
1. You can set the station number.However, you can only connect a single personal computer to a single inverter.2. You can set communication by choosing Tool... More Details >>
- No:21882
- Release Date:2018/08/22 16:29
-
If "1" is not shown on the frequency monitor, some of the parameters necessary for auto tuning may not be set correctly.Set rated motor current of Pr.81 (Num... More Details >>
- No:21751
- Release Date:2018/08/22 16:29
-
The error LED on the master side of the programmable controller blinks (faulty station present).According to the SW80 station information, an error flag is a... More Details >>
- No:21813
- Release Date:2018/08/22 16:29
-
This subroutine is to check the data link status and needs to be executed only once at the start of the program. More Details >>
- No:21767
- Release Date:2018/08/22 16:29
-
After setting Pr.340 to "10", you need to power OFF then ON the inverter to make the new setting enabled because you are setting the operation upon power-on.... More Details >>
- No:21759
- Release Date:2018/08/22 16:29