FAQ within [ FREQROL-A700 ]

311-320 of Total 351

prev 32 / 36page next
  • Display unit of operation panel

    Set the rotations per minute that is obtained while operating at the frequency set with Pr.505 (Speed setting reference) to Pr.37 (Speed display).For example... More Details >>

    • No:21774
    • Release Date:2018/08/22 16:29
  • Setting resolution switching

    Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>

    • No:21161
    • Release Date:2018/08/22 16:26
  • Orientation control

    The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>

    • No:21162
    • Release Date:2018/08/22 16:26
  • Electronic bypass function

    With the automatic bypass sequence (Pr.139 ≠ 9999, Pr.159 = 9999), the motor operation is switched to commercial power supply operation when the output frequ... More Details >>

    • No:21189
    • Release Date:2018/08/22 16:26
  • FR-A800

    Yes. More Details >>

    • No:20959
    • Release Date:2018/08/22 16:25
  • Output frequency monitor value

    When running the inverter after auto tuning, the frequency setting value is increased by the amount of the motor slippage, resulting in a higher monitor valu... More Details >>

    • No:21781
    • Release Date:2018/08/22 16:29
  • Real sensorless vector control

    The FR-A700 supports Real sensorless vector control.   More Details >>

    • No:21714
    • Release Date:2018/08/22 16:29
  • Stop-on-contact control

    Set Pr.270 (Stop-on-contact control) to "1".Set Pr.184 (RES terminal function selection) to "3" to choose the RT signal function.When the terminals RL and RT... More Details >>

    • No:21691
    • Release Date:2018/08/22 16:28
  • CC-Link

    The start commands cannot be input from both sources simultaneously because the operation command source is specified.You can switch the command source as ne... More Details >>

    • No:21828
    • Release Date:2018/08/22 16:29
  • Frequency setting

    When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>

    • No:21801
    • Release Date:2018/08/22 16:29