Even though the maximum frequency setting is changed using CC-Link, the running frequency is not changed. By writing the set frequency to the remote register... More Details >>
- No:21346
- Release Date:2018/08/22 16:27
-
The 75K or higher DC reactor is included in the 75K or higher inverter. The option cannot be purchased separately. More Details >>
- No:21252
- Release Date:2018/08/22 16:26
-
Output frequency monitor value
When running the inverter after auto tuning, the frequency setting value is increased by the amount of the motor slippage, resulting in a higher monitor valu... More Details >>
- No:21781
- Release Date:2018/08/22 16:29
-
Set Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96. More Details >>
- No:21721
- Release Date:2018/08/22 16:29
-
The value of Pr.20 (Acceleration/deceleration standard frequency) is corresponding to 1 s. (Initial value: 60 Hz) More Details >>
- No:21185
- Release Date:2018/08/22 16:26
-
Check if any device is connected to the inverter's external terminal.In particular, check if MRS and SD are short-circuited.If they are short-circuited, open... More Details >>
- No:21753
- Release Date:2018/08/22 16:29
-
Advanced magnetic flux vector control
It can be used with the FR-A700 and FR-E700 series. More Details >>
- No:21298
- Release Date:2018/08/22 16:26
-
Check that the correct rated motor current is set in Pr.9 (Electronic thermal O/L relay). No parameter is available for setting the operation time of the ele... More Details >>
- No:21291
- Release Date:2018/08/22 16:26
-
Set "33" or "34". More Details >>
- No:21167
- Release Date:2018/08/22 16:26
-
The AC reactor (FR-HAL) is built in the FR-A701. (The circuit type in the Harmonic Suppression Guidelines is three-phase bridge (capacitor smoothed), with re... More Details >>
- No:21011
- Release Date:2018/08/22 16:25