  • FR-A701

    It is protected not by observing the temperature directly, but by estimating it from the current value, output frequency, and carrier frequency. More Details >>

    • No:20871
    • Release Date:2018/08/22 16:24
  • FR-A800

    Yes. More Details >>

    • No:20959
    • Release Date:2018/08/22 16:25
  • Overseas inverter models

    "□□□□□" in the model name of the FR-A700 series and FR-F700 series with the multiple ratings is as follows. "□□□□□" in the model name of the FR-A700 series a... More Details >>

    • No:20993
    • Release Date:2018/08/22 16:25
  • FR-A701

    The AC reactor (FR-HAL) is built in the FR-A701. (The circuit type in the Harmonic Suppression Guidelines is three-phase bridge (capacitor smoothed), with re... More Details >>

    • No:21011
    • Release Date:2018/08/22 16:25
  • Sine wave filter

    The sine wave filter can be applied only under V/F control. When Pr.72 PWM frequency selection is set to 25, V/F control is set automatically. The applicable... More Details >>

    • No:21068
    • Release Date:2018/08/22 16:25
  • FR-A800

    No. Check the parameter setting of the A700, and then adjust the parameter setting of the A800 to those of the A700. For the details, refer to the replacemen... More Details >>

    • No:21107
    • Release Date:2018/08/22 16:25
  • FR-A800

    - The 280K or lower has the installation size compatibility. - The 315K or higher does not have the installation compatibility; because the inverter unit and... More Details >>

    • No:21109
    • Release Date:2018/08/22 16:25
  • FR-A700

    The leakage current is 1 mA because the circuit constant in the EMC filter of A720-0.4K and 0.75K are different. More Details >>

    • No:21120
    • Release Date:2018/08/22 16:26
  • Reverse rotation prevention selection

    Yes, it does. When the inverter is coasting in the reverse direction, it starts in the reverse direction and switches to the forward rotation after a deceler... More Details >>

    • No:21125
    • Release Date:2018/08/22 16:26
  • Wiring length

    Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>

    • No:21133
    • Release Date:2018/08/22 16:26