FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A500
FAQ
Keyword Search
FREQROL-A500
FAQ within [ FREQROL-A500 ]
-
Inverter stop-on-contact control
Use the FREQROL-A500 series inverter with the optional FR-A5NC.Then, you can implement both of stop-on-contact control and CC-Link operation. More Details >>
- No:22089
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Inverter operation at instantaneous power failure
When performing the automatic restart after instantaneous power failure, input the operation signal (STF or STR) and selection of automatic restart after ins... More Details >>
- No:21371
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Using FR-A540 inverter on CC-Link
Answer to question 1 When the CC-Link option goes faulty, OPT (option error) occurs and the inverter's fault output is triggered. When communication is lost ... More Details >>
- No:21391
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Since the FR-A540-0.75K has a brake transistor for resistor regenerative driving inside the inverter, you do not need to use BU. Just remove the jumper from ... More Details >>
- No:21992
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Torque characteristic at low speed
Torque is not guaranteed for slower than 0.5 Hz. Therefore, no data for this is published. Also, no torque is generated at 0 Hz. More Details >>
- No:21543
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
You cannot disable the error display. The OC1 overcurrent alarm is displayed. The condition to display this alarm is that the main circuit power supply is OF... More Details >>
- No:21535
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
When the inverter output shutoff signal MRS is turned on, the output is shut off immediately without regard to setting of Pr.250. More Details >>
- No:21423
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
When you use a long wire between the inverter and motor, pay attention to the following: 1. Since the voltage supplied to the motor terminal is reduced due t... More Details >>
- No:21441
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
After inputting the start signal performing the tuning, output the output frequency. The tuning ends in approximately 500 ms in maximum after started. Durin... More Details >>
- No:21372
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The inverter does not have a function to limit the current at 0 Hz.Although it has the DC injection brake, it is intended to improve the braking capability b... More Details >>
- No:22002
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
111-120 of Total 123