Term definition and advanced magnetic flux control
1. Maximum torque available for output from the motor when combined with an inverter for a short period of time (1 minute or less). It depends on the contr... More Details >>
- No:21541
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
1. You can implement stop-on-contact.2. When implementing stop-on-contact, use the inverter to decelerate the motors to reduce the impact upon stop-on-contac... More Details >>
- No:22041
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>
- No:21976
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500 , FREQROL-F500
-
Load current limit of inverter
You can input current from the terminal AM of the inverter to the programmable controller (for A/D conversion) and control the speed with the software of the... More Details >>
- No:21419
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
No. Check the parameter setting of the A500(L), and then adjust the parameter setting of the A800 to those of the A500(L). For the details, refer to the repl... More Details >>
- No:21108
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-A500
-
Calculation of inverter acceleration and deceleration time
Refer to the Technical Sheet No.23 (Capacity Selection and Continuous Operation) for reference for selection. Optional capacity selection software is also pr... More Details >>
- No:22097
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The inverter uses PWM control to change the output voltage and frequency to vary the motor speed. PWM stands for Pulse Width Modulation. Voltage is chopped i... More Details >>
- No:21549
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
"8" display in offline auto tuning means forced stop by the operator. This means that you stopped operation before tuning completes. With this forced stop, ... More Details >>
- No:21527
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Controlling multiple VVVFs via communication from personal computer
To control multiple inverters using arbitrary signals (4 to 20 mA) simultaneously, it is recommended to connect the signals (4 to 20 mA) in series. (This doe... More Details >>
- No:21491
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
- The installation size is compatible for the following capacities. Compatible: 200 V class 90K or lower, 400 V class 7.5K or lower and 18.5K to 280K- The in... More Details >>
- No:21110
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-A500