FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A500
FAQ
Keyword Search
FREQROL-A500
FAQ within [ FREQROL-A500 ]
-
Concurrent monitoring of running frequency, output voltage, and output current
Add an analog output by the FR-A5AY.Monitor the three output; output AM (0 to 5 (10) V) and optional 4 to 20 mA, and 0 to 5 (10) V. More Details >>
- No:21959
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-F500
-
Current value on input side and output side
1. When slight imbalance (approximately 5%) is present with the inverter power supply voltage, the inverter input current can get imbalanced significantly. I... More Details >>
- No:21476
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
1. By changing RWw1 while RYD is ON, you can change the inverter's frequency.You cannot do this with RYE. You need to turn OFF and then ON RYE each time you ... More Details >>
- No:22083
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
12-bit digital input and others
You can switch between PU operation and external operation using the plug-in option "12-bit digital input" card and external contact signals. After setting P... More Details >>
- No:21432
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
Connection with personal computer
Connection method for the A500 and E500 is shown in the figure below. The figure is given in an Excel file. Figure 1 More Details >>
- No:21536
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>
- No:22082
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
External wiring for CC-Link operation
For the combination of the FR-A500 + FR-A5NC, Pr.338 and Pr.339 are used to specify whether the external signals or CC-Link commands are used to set the runn... More Details >>
- No:21973
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
You can set both the BCD code and binary code inputs within the range from 0 to 400 Hz.You can set the bias and gain in 0.01 Hz units.For BCD input, when the... More Details >>
- No:21945
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500
-
Imbalanced input and output side power supplies
1. In general, the input power of the inverter is always larger than the output power because the inverter loss is added to the motor loss. 2. In both of cas... More Details >>
- No:21473
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others , FREQROL-A500
31-40 of Total 123