FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A024
FAQ
Keyword Search
FAQ within [ FREQROL-A024 ]
-
What happens if reset occurs during operation?
This is because when the inverter restarts while the motor is coasting, an overcurrent trip can occur during the restart process. However, the recent types o... More Details >>
- No:21477
- Release Date:2018/08/22 16:27
-
Driving 200 V motor by 400 V inverter
A 400 V inverter does not operate when 200 V is supplied to it, therefore the motor does not rotate. A 200 V motor can be rotated by a 400 V inverter, howeve... More Details >>
- No:21446
- Release Date:2018/08/22 16:27
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
-
Features of parameter unit FR-PU03
This parameter unit realizes both easy operation and advanced operation. In normal operation, you only need to use six keys for easy operation. To perform ad... More Details >>
- No:21614
- Release Date:2018/08/22 16:28
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
-
1. Choose the circuit breaker based on the inverter capacity. 2. Also, choose the brake resistor based on the inverter capacity. 3. Choose the AC reactor bas... More Details >>
- No:21425
- Release Date:2018/08/22 16:27
-
Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>
- No:22028
- Release Date:2018/08/22 16:30
-
Energy saving effect of inverter operation
Energy saving operation of the inverter is represented by comparison with commercial power supply operation. For example, to control air volume of an air co... More Details >>
- No:21622
- Release Date:2018/08/22 16:28
-
What functions are added by upgrading?
The following functions are added by upgrading: - Slip compensation function- Serial communication function- Frequency jump- 15-speed operation- Zero current... More Details >>
- No:21619
- Release Date:2018/08/22 16:28
-
Difference in purpose from FR-A200 series
Reference of proper use of each series is as follows: - A024: When balance between size, performance, and cost is important. - A200: When system configuratio... More Details >>
- No:21610
- Release Date:2018/08/22 16:28
11-20 of Total 40