    During non-low-noise operation (initial setting) with the carrier frequency of 1 kHz, both noise and leakage current levels are almost same as the Z024 serie... More Details >>

    • No:21606
    • Release Date:2018/08/22 16:28
  • Difference in purpose from FR-A200 series

    Reference of proper use of each series is as follows: - A024: When balance between size, performance, and cost is important. - A200: When system configuratio... More Details >>

    • No:21610
    • Release Date:2018/08/22 16:28
  • Types available for FR-AU03

    The FR-AU03 is a dedicated product for the FR-A024. Although it cannot be attached directly to other inverters (FR-A200 and FR-Z, FR-U series), it can be use... More Details >>

    • No:21603
    • Release Date:2018/08/22 16:28
  • FR-A024

    Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>

    • No:21170
    • Release Date:2018/08/22 16:26
  • Monitor output

    The FM output is the 1440 Hz, 1 mA pulse train output at full scale. You can input to the programmable controller if it has a pulse train input. A68AD does n... More Details >>

    • No:21439
    • Release Date:2018/08/22 16:27
  • What functions are added by upgrading?

    The following functions are added by upgrading: - Slip compensation function- Serial communication function- Frequency jump- 15-speed operation- Zero current... More Details >>

    • No:21619
    • Release Date:2018/08/22 16:28
  • Can I use the parameter unit FR-PU02?

    Yes, but functions are partially limited. (The FR-PU02 cannot demonstrate its full ability. The FR-PU01 cannot be used.) To use the parameter unit FR-PU02, u... More Details >>

    • No:21613
    • Release Date:2018/08/22 16:28
  • General-purpose magnetic flux control

    Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>

    • No:21620
    • Release Date:2018/08/22 16:28
  • Thermal protection

    Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>

    • No:21397
    • Release Date:2018/08/22 16:27
  • How many inverters can I connect using the communication unit?

    Since the communication unit conforms to the EIA Standard RS-485, up to 32 inverters can be connected. (Transmission format: Multidrop link, total wiring len... More Details >>

    • No:21616
    • Release Date:2018/08/22 16:28