The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
-
Number of inverters that can be connected to a 20 A branch circuit breaker
The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>
- No:21508
- Release Date:2018/08/22 16:28
-
"E.OV3" is displayed when the voltage between the inverter terminals PN rises abnormally high while the inverter is decelerating or stopped. In this case, th... More Details >>
- No:21411
- Release Date:2018/08/22 16:27
-
Features of parameter unit FR-PU03
This parameter unit realizes both easy operation and advanced operation. In normal operation, you only need to use six keys for easy operation. To perform ad... More Details >>
- No:21614
- Release Date:2018/08/22 16:28
-
Countermeasure against noise and leakage current during low-noise operation
The following two major countermeasures against noise are available: - Keep the noise source and partner device apart from each other.- Install a noise filte... More Details >>
- No:21605
- Release Date:2018/08/22 16:28
-
General-purpose magnetic flux control
Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>
- No:21620
- Release Date:2018/08/22 16:28
-
Can I replace the cooling fan alone?
The fan of the FR-A024 cannot be replaced by the customer. Mitsubishi Electric System & Service will replace it, so contact us to order it. More Details >>
- No:22001
- Release Date:2018/08/22 16:30
-
How much low-speed torque can be output?
By choosing the General-purpose magnetic flux vector control and slip compensation function, you can output torque of 150% or more at 1 Hz (200% or more at 3... More Details >>
- No:21618
- Release Date:2018/08/22 16:28
-
Countermeasure against the instantaneous power failure with the inverter
The power cannot be supplied to the control power supply separately for the FR-A024/A044 and small type FR-E500. Therefore, the UPS is not available. More Details >>
- No:21368
- Release Date:2018/08/22 16:27
-
Driving 200 V motor by 400 V inverter
A 400 V inverter does not operate when 200 V is supplied to it, therefore the motor does not rotate. A 200 V motor can be rotated by a 400 V inverter, howeve... More Details >>
- No:21446
- Release Date:2018/08/22 16:27