"E.OV3" is displayed when the voltage between the inverter terminals PN rises abnormally high while the inverter is decelerating or stopped. In this case, th... More Details >>
- No:21411
- Release Date:2018/08/22 16:27
-
Synchronous operation of two motors
When synchronously operating two motors, you need to detect speed from both motors. Each inverter is controlled based on this speed detection signal. As an e... More Details >>
- No:21540
- Release Date:2018/08/22 16:28
-
General-purpose magnetic flux control
Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>
- No:21620
- Release Date:2018/08/22 16:28
-
You can use it with the FR-A200 (E) and FR-A100 (E) series. (Note) Use the connection cable (option). You cannot use it with the FR-Z and FR-U series (except... More Details >>
- No:21615
- Release Date:2018/08/22 16:28
-
Countermeasure against noise and leakage current during low-noise operation
The following two major countermeasures against noise are available: - Keep the noise source and partner device apart from each other.- Install a noise filte... More Details >>
- No:21605
- Release Date:2018/08/22 16:28
-
Countermeasure against the instantaneous power failure with the inverter
The power cannot be supplied to the control power supply separately for the FR-A024/A044 and small type FR-E500. Therefore, the UPS is not available. More Details >>
- No:21368
- Release Date:2018/08/22 16:27
-
Number of inverters that can be connected to a 20 A branch circuit breaker
The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>
- No:21508
- Release Date:2018/08/22 16:28
-
Can I replace the cooling fan alone?
The fan of the FR-A024 cannot be replaced by the customer. Mitsubishi Electric System & Service will replace it, so contact us to order it. More Details >>
- No:22001
- Release Date:2018/08/22 16:30
-
Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>
- No:21397
- Release Date:2018/08/22 16:27
-
Details of zero current detection
1. The inverter also monitors the output current during DC injection brake operation in addition to normal operation. Therefore, zero current detection also ... More Details >>
- No:21481
- Release Date:2018/08/22 16:27