  • Synchronous operation of two motors

    When synchronously operating two motors, you need to detect speed from both motors. Each inverter is controlled based on this speed detection signal. As an e... More Details >>

    • No:21540
    • Release Date:2018/08/22 16:28
  • Can I replace the cooling fan alone?

    The fan of the FR-A024 cannot be replaced by the customer. Mitsubishi Electric System & Service will replace it, so contact us to order it. More Details >>

    • No:22001
    • Release Date:2018/08/22 16:30
  • Parameter unit FR-PU03

    You can use it with the FR-A200 (E) and FR-A100 (E) series. (Note) Use the connection cable (option). You cannot use it with the FR-Z and FR-U series (except... More Details >>

    • No:21615
    • Release Date:2018/08/22 16:28
  • Features of parameter unit FR-PU03

    This parameter unit realizes both easy operation and advanced operation. In normal operation, you only need to use six keys for easy operation. To perform ad... More Details >>

    • No:21614
    • Release Date:2018/08/22 16:28
  • Speed control range

    Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>

    • No:22028
    • Release Date:2018/08/22 16:30
  • Model configuration

    The following seven models are available for the 200 V class: 0.1K, 0.2K, 0.4K, 0.75K, 1.5K, 2.2K, and 3.7K The following five models are available for the 4... More Details >>

    • No:21621
    • Release Date:2018/08/22 16:28
  • General-purpose magnetic flux control

    Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>

    • No:21620
    • Release Date:2018/08/22 16:28
  • Do noise and leakage current increase?

    During non-low-noise operation (initial setting) with the carrier frequency of 1 kHz, both noise and leakage current levels are almost same as the Z024 serie... More Details >>

    • No:21606
    • Release Date:2018/08/22 16:28
  • Can I connect it to high power factor converter?

    It can be connected to an inverter that supports the high power factor converter FR-HC. (It cannot be connected to conventional inverters.) How to identify i... More Details >>

    • No:21602
    • Release Date:2018/08/22 16:28
  • Details of zero current detection

    1. The inverter also monitors the output current during DC injection brake operation in addition to normal operation. Therefore, zero current detection also ... More Details >>

    • No:21481
    • Release Date:2018/08/22 16:27