- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A024
FAQ
Keyword Search
FAQ within [ FREQROL-A024 ]
-
Since the inverter power supply uses the single-phase input, you cannot use a 0.75K inverter with a 0.6 kW motor to draw the maximum ability of the motor. To... More Details >>
- No:21470
- Release Date:2018/08/22 16:27
-
Synchronous operation of two motors
When synchronously operating two motors, you need to detect speed from both motors. Each inverter is controlled based on this speed detection signal. As an e... More Details >>
- No:21540
- Release Date:2018/08/22 16:28
-
Countermeasure against noise and leakage current during low-noise operation
The following two major countermeasures against noise are available: - Keep the noise source and partner device apart from each other.- Install a noise filte... More Details >>
- No:21605
- Release Date:2018/08/22 16:28
-
A plug-in option cannot be installed on the FREQROL-A024 series. If you need a plug-in option's function, use other series of inverters such as the FREQROL-A... More Details >>
- No:21608
- Release Date:2018/08/22 16:28
-
You can vary the carrier frequency within the range of 0.7 to 14.5 kHz, and it is initially set to 1 kHz that generates low noise and leakage current. You ca... More Details >>
- No:21607
- Release Date:2018/08/22 16:28
-
What functions are added by upgrading?
The following functions are added by upgrading: - Slip compensation function- Serial communication function- Frequency jump- 15-speed operation- Zero current... More Details >>
- No:21619
- Release Date:2018/08/22 16:28
-
"E.OV3" is displayed when the voltage between the inverter terminals PN rises abnormally high while the inverter is decelerating or stopped. In this case, th... More Details >>
- No:21411
- Release Date:2018/08/22 16:27
-
Installation of new serial communication unit FR-CU03
Remove the parameter unit FR-PU03 and install there. (The installation dimensions of the FR-CU03 are the same as the FR-PU.) You can read and write parameter... More Details >>
- No:21617
- Release Date:2018/08/22 16:28
-
Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>
- No:22028
- Release Date:2018/08/22 16:30
-
Can I connect it to high power factor converter?
It can be connected to an inverter that supports the high power factor converter FR-HC. (It cannot be connected to conventional inverters.) How to identify i... More Details >>
- No:21602
- Release Date:2018/08/22 16:28
21-30 of Total 40