  • Operation frequency

    I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>

    • No:21474
    • Release Date:2018/08/22 16:27
  • External thermal overheat

    Take the following countermeasure:1. If the thermal trips in low-speed operation, trips can be avoided, depending on the external thermal relay operation cha... More Details >>

    • No:21954
    • Release Date:2018/08/22 16:30
  • I want to shorten deceleration time of small capacity motor

    You can use an inverter with a larger capacity than the motor. You cannot connect a brake resistor to the FR-E520-0.1K and 0.2K. With the FR-E520-0.1K or 0.2... More Details >>

    • No:21463
    • Release Date:2018/08/22 16:27
  • Using built-in potentiometer and multi-speed together

    Yes. Set Pr.79 = 3. (Input the start signal from an external source.) More Details >>

    • No:21950
    • Release Date:2018/08/22 16:30
  • Alarm output signal when using CC-Link

    The RX7 output signal is the same as the signals for NO, NC, and transfer contact output.You can change the contents of this output signal using Pr.192.Pr.19... More Details >>

    • No:22008
    • Release Date:2018/08/22 16:30
  • Usage

    1. Changing frequency to 0 Hz(1) Set Pr.8 (Deceleration time) to 0 second.If the load is large, the stall prevention function may work to lengthen decelerati... More Details >>

    • No:22019
    • Release Date:2018/08/22 16:30
  • Analog output

    The FM output is 0 to 8 VDC pulse. More Details >>

    • No:22039
    • Release Date:2018/08/22 16:30
  • Notes when inverter capacity is larger than motor capacity

    When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>

    • No:22040
    • Release Date:2018/08/22 16:30
  • Parameter unit display

    Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>

    • No:22072
    • Release Date:2018/08/22 16:30
  • Monitor

    The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>

    • No:21373
    • Release Date:2018/08/22 16:27