Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-E500 ]

11-20 of Total 85

prev 2 / 9page next
  • Speed 15 operation

    Using the inverter's input terminal, you can use up to 15 speeds.This function is supported by the current 500 series products (A500, F500, E500, and S500).U... More Details >>

    • No:21947
    • Release Date:2018/08/22 16:30
  • Parameter No.79 (Operation mode)

    You cannot cancel multi-speed command input. When the multi-speed command is input from the terminal, you cannot use the potentiometer. Use the inverter so t... More Details >>

    • No:21467
    • Release Date:2018/08/22 16:27
  • Err display on operation panel

    The following causes are probable for this Err display:- Operation error (for example, you tried to input a value other than the available range of parameter... More Details >>

    • No:22063
    • Release Date:2018/08/22 16:30
  • UL standard certification number

    The UL standard certification numbers (UL Listing Card No.) of the FR-E500, FR-A500, and FR-A200 are as follows: FR-A200 series??????E131592FR-A500 series???... More Details >>

    • No:21506
    • Release Date:2018/08/22 16:28
  • Dealing with Err.

    The following causes are probable for persistent Err. display: 1. The terminals RES and SD are always short-circuited. 2. Operation panel contact or operatio... More Details >>

    • No:21412
    • Release Date:2018/08/22 16:27
  • Difference between SU (up to frequency) and FU (frequency detection)

    - SU signal (up to frequency signal)This signal is output when the inverter output frequency reaches the set frequency (the frequency the inverter is require... More Details >>

    • No:21436
    • Release Date:2018/08/22 16:27
  • Speed change due to power supply voltage fluctuation

    1. The output frequency satisfies the "control specification/frequency precision" even when the power supply voltage changes, but the output voltage cannot r... More Details >>

    • No:22069
    • Release Date:2018/08/22 16:30
  • Permissible brake duty

    When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>

    • No:22074
    • Release Date:2018/08/22 16:30
  • Output side earth (ground) fault overcurrent protection

    1. How much is the sensitivity current? When the sum of the three-phase output current of the inverter reaches approximately 70% of the inverter rated curren... More Details >>

    • No:21394
    • Release Date:2018/08/22 16:27
  • Inverter

    You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>

    • No:22082
    • Release Date:2018/08/22 16:30

11-20 of Total 85