FAQ within [ FREQROL-E500 ]

21-30 of Total 84

prev 3 / 9page next
  • Communication operation with FR-E500

    We have no sample program for RS485 communication. Since the communication method of the FR-SW0-SETUP uses a different protocol from 485 communication and st... More Details >>

    • No:21451
    • Release Date:2018/08/22 16:27
  • I want to synchronize the Z200 and E500.

    If you are using analog voltage commands, connect the voltage inputs to the FR-E500 and FR-Z200 in parallel to equalize inputs to both units and speeds are s... More Details >>

    • No:21929
    • Release Date:2018/08/22 16:30
  • Items controllable via CC-Link

    1. Not all items can be controlled.   - Functions that cannot be controlled JOG, AU, CS, OH, X10, X11, X12, and X16 functions (Other functions can be control... More Details >>

    • No:21459
    • Release Date:2018/08/22 16:27
  • Brake resistor

    Connecting the brake resistor allows for quick deceleration because the regenerative power is processed. (The brake torque increases.)Therefore, when an exte... More Details >>

    • No:22045
    • Release Date:2018/08/22 16:30
  • Speed 15 operation

    Using the inverter's input terminal, you can use up to 15 speeds.This function is supported by the current 500 series products (A500, F500, E500, and S500).U... More Details >>

    • No:21947
    • Release Date:2018/08/22 16:30
  • CC-Link

    Already released.Unlike the E520, you need to purchase the optional card FR-E5NC. More Details >>

    • No:22050
    • Release Date:2018/08/22 16:30
  • External wiring for CC-Link operation

    For the combination of the FR-A500 + FR-A5NC, Pr.338 and Pr.339 are used to specify whether the external signals or CC-Link commands are used to set the runn... More Details >>

    • No:21973
    • Release Date:2018/08/22 16:30
  • Overcurrent

    Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>

    • No:21430
    • Release Date:2018/08/22 16:27
  • Connection with personal computer

    Connection method for the A500 and E500 is shown in the figure below. The figure is given in an Excel file. Figure 1 More Details >>

    • No:21536
    • Release Date:2018/08/22 16:28
  • Err display on operation panel

    The following causes are probable for this Err display:- Operation error (for example, you tried to input a value other than the available range of parameter... More Details >>

    • No:22063
    • Release Date:2018/08/22 16:30