  • Analog output

    The FM output is 0 to 8 VDC pulse. More Details >>

    • No:22039
    • Release Date:2018/08/22 16:30
  • FR-E520 operation mode (Pr.79) selection

    The FR-E500 manufactured before May 1998 behaved as you mentioned, and the potentiometer becomes unavailable once you set the frequency on the operation pane... More Details >>

    • No:21525
    • Release Date:2018/08/22 16:28
  • Soft-PWM

    The inverter uses PWM control to change the output voltage and frequency to vary the motor speed. PWM stands for Pulse Width Modulation. Voltage is chopped i... More Details >>

    • No:21549
    • Release Date:2018/08/22 16:28
  • Inverter

    You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>

    • No:22082
    • Release Date:2018/08/22 16:30
  • Direct driven start by power supply

    The warning "Do not use a magnetic contactor on the inverter input for frequent starting/stopping of the inverter." is indicated in the precautions at the be... More Details >>

    • No:21458
    • Release Date:2018/08/22 16:27
  • FR-E520 7.5 kW model

    The outline dimensions of the FR-E520-7.5K are 180W×260H×170D. More Details >>

    • No:21521
    • Release Date:2018/08/22 16:28
  • Brake resistor

    Connecting the brake resistor allows for quick deceleration because the regenerative power is processed. (The brake torque increases.)Therefore, when an exte... More Details >>

    • No:22045
    • Release Date:2018/08/22 16:30
  • Inverter outline dimension CAD data

    The outline dimension diagram is found on the member's page of Mitsubishi Electric FA Global Website.Contact our sales personnel for details on the programma... More Details >>

    • No:22053
    • Release Date:2018/08/22 16:30
  • Control circuit power supply

    If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>

    • No:22096
    • Release Date:2018/08/22 16:30
  • Operation at external operation/stop

    It is recommended to turn OFF the start signals (STF and STR) when stopping the inverter.In this case, it is not probable that the motor rotates due to a cal... More Details >>

    • No:22102
    • Release Date:2018/08/22 16:31