General-purpose magnetic flux vector control is effective at low speed under a heavy load.To shorten the acceleration time, use Pr.44 to set the second accel... More Details >>
- No:22059
- Release Date:2018/08/22 16:30
-
Instantaneous power failure of facilities
1. If the start signal is present when the power and communication restore, the inverter starts operation. 2. Similarly to the above, if the start signal is ... More Details >>
- No:22093
- Release Date:2018/08/22 16:30
-
1. Pr.146 is not available. Some catalogs and manuals cover this parameter, but it is an error. The latest catalogs and manuals have been corrected to el... More Details >>
- No:21529
- Release Date:2018/08/22 16:28
-
The brake resistor is not built in the inverter. Purchase the optional resistor and connect it to the inverter.Inverter only (without resistor)Continuous reg... More Details >>
- No:21989
- Release Date:2018/08/22 16:30
-
The internal processing speed is not published. The analog input specifications are as follows: FR-A500???1/4000FR-E500???1/1000MR-H???1/4000 More Details >>
- No:21550
- Release Date:2018/08/22 16:28
-
Speed 2 operation with potentiometer on operation panel
Yes. Set parameters as below.For FR-E500Set Pr.79 =3, and Pr.146= 0.Multi-speed is prioritized.For FR-S500Set Pr.79 = 3, and Pr.53 = 1.Multi-speed is priorit... More Details >>
- No:21963
- Release Date:2018/08/22 16:30
-
1. Can I set the frequency by the external potentiometer when multi-speed signal is 0 (nothing is input)?-> It is possible by using the external operation... More Details >>
- No:21990
- Release Date:2018/08/22 16:30
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
-
Indication of potentiometer on operation panel
The potentiometer on the operation panel is initially calibrated so that the maximum indication is slightly over 60 Hz with the potentiometer turned to the m... More Details >>
- No:21427
- Release Date:2018/08/22 16:27
-
Direct driven start by power supply
The warning "Do not use a magnetic contactor on the inverter input for frequent starting/stopping of the inverter." is indicated in the precautions at the be... More Details >>
- No:21458
- Release Date:2018/08/22 16:27