FAQ within [ FREQROL-E500 ]

51-60 of Total 84

prev 6 / 9page next
  • Noise from motor at low speed

    It is considered to be caused by inverter PWM control. It can be suppressed by raising the PWM carrier frequency (Pr.72), but the entire noise and leakage cu... More Details >>

    • No:21428
    • Release Date:2018/08/22 16:27
  • Detection of the motor load

    An inverter is used to rotate a motor but it cannot be used to detect whether the belt is broken or not. However, the magnitude of the load will change when ... More Details >>

    • No:21387
    • Release Date:2018/08/22 16:27
  • Countermeasures when input power supply is turned off upon equipment fault

    1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>

    • No:21390
    • Release Date:2018/08/22 16:27
  • Speed 2 operation with potentiometer on operation panel

    Yes. Set parameters as below.For FR-E500Set Pr.79 =3, and Pr.146= 0.Multi-speed is prioritized.For FR-S500Set Pr.79 = 3, and Pr.53 = 1.Multi-speed is priorit... More Details >>

    • No:21963
    • Release Date:2018/08/22 16:30
  • Analog signal resolution

    The internal processing speed is not published. The analog input specifications are as follows: FR-A500???1/4000FR-E500???1/1000MR-H???1/4000 More Details >>

    • No:21550
    • Release Date:2018/08/22 16:28
  • Overcurrent

    Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>

    • No:21430
    • Release Date:2018/08/22 16:27
  • Clutch connection of load

    Since a large load is applied to the motor when the electromagnetic clutch turns on, overcurrent may occur if the load is heavy. To ensure that the rated cur... More Details >>

    • No:21955
    • Release Date:2018/08/22 16:30
  • Inverter general matters

    1. To perform emergency stop, it is recommended to have the motor coast and stop it using a mechanical brake.In this case, the output stop (MRS) signal is in... More Details >>

    • No:22103
    • Release Date:2018/08/22 16:31
  • Items controllable via CC-Link

    1. Not all items can be controlled.   - Functions that cannot be controlled JOG, AU, CS, OH, X10, X11, X12, and X16 functions (Other functions can be control... More Details >>

    • No:21459
    • Release Date:2018/08/22 16:27
  • External thermal overheat

    Take the following countermeasure:1. If the thermal trips in low-speed operation, trips can be avoided, depending on the external thermal relay operation cha... More Details >>

    • No:21954
    • Release Date:2018/08/22 16:30