FAQ within [ FREQROL-E500 ]

51-60 of Total 84

prev 6 / 9page next
  • Operation panel

    Be sure to use the FR-E5P to mount the operation panel.This is because the board is bare on the back of the operation panel and a dedicated connector is requ... More Details >>

    • No:22030
    • Release Date:2018/08/22 16:30
  • Permissible brake duty

    When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>

    • No:22074
    • Release Date:2018/08/22 16:30
  • Parameter setting

    1. Pr.146 is not available.   Some catalogs and manuals cover this parameter, but it is an error.   The latest catalogs and manuals have been corrected to el... More Details >>

    • No:21529
    • Release Date:2018/08/22 16:28
  • Operation at external operation/stop

    It is recommended to turn OFF the start signals (STF and STR) when stopping the inverter.In this case, it is not probable that the motor rotates due to a cal... More Details >>

    • No:22102
    • Release Date:2018/08/22 16:31
  • CC-Link

    Although you specify the FR-V200 and others as the inverter models, CC-Link is currently supported by the FR-A500 and FR-E500. The FR-V200E does not support ... More Details >>

    • No:21499
    • Release Date:2018/08/22 16:27
  • Current monitor display

    The current monitor displays the average value of the three-phase current. The three-phase voltage is not incorporated for the voltage monitor. The output vo... More Details >>

    • No:21376
    • Release Date:2018/08/22 16:27
  • Overcurrent

    Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>

    • No:21430
    • Release Date:2018/08/22 16:27
  • Speed does not exceed 46 Hz

    Since the inverter displayed "0.00" instead of an error when the inverter speed dropped to 0 Hz and stopped by holding the winding machine by hand, it is con... More Details >>

    • No:21492
    • Release Date:2018/08/22 16:27
  • Countermeasures when input power supply is turned off upon equipment fault

    1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>

    • No:21390
    • Release Date:2018/08/22 16:27
  • External wiring for CC-Link operation

    For the combination of the FR-A500 + FR-A5NC, Pr.338 and Pr.339 are used to specify whether the external signals or CC-Link commands are used to set the runn... More Details >>

    • No:21973
    • Release Date:2018/08/22 16:30